20
9469300991 Rev A
Default Register Table
DGC-2020HD Modbus
™ Protocol
Name
Description
Group Register Type Bytes R/W
Unit
Range
CEM 3 Contact Input 6 Contact Recognition
GG
0666
Uint32 4
R W n/a
Always=0
Engine Running=1
CEM 3 Contact Input 6 Alarm Configuration
GG
0668
Uint32 4
R W n/a
Status Only=0
Pre-Alarm=1
Alarm=2
CEM 3 Contact Input 6 Activation Delay
GG
0670
Uint32 4
R W Second
0 - 300
CEM 3 Contact Input 7 Contact Recognition
GG
0672
Uint32 4
R W n/a
Always=0
Engine Running=1
CEM 3 Contact Input 7 Alarm Configuration
GG
0674
Uint32 4
R W n/a
Status Only=0
Pre-Alarm=1
Alarm=2
CEM 3 Contact Input 7 Activation Delay
GG
0676
Uint32 4
R W Second
0 - 300
CEM 3 Contact Input 8 Contact Recognition
GG
0678
Uint32 4
R W n/a
Always=0
Engine Running=1
CEM 3 Contact Input 8 Alarm Configuration
GG
0680
Uint32 4
R W n/a
Status Only=0
Pre-Alarm=1
Alarm=2
CEM 3 Contact Input 8 Activation Delay
GG
0682
Uint32 4
R W Second
0 - 300
CEM 3 Contact Input 9 Contact Recognition
GG
0684
Uint32 4
R W n/a
Always=0
Engine Running=1
CEM 3 Contact Input 9 Alarm Configuration
GG
0686
Uint32 4
R W n/a
Status Only=0
Pre-Alarm=1
Alarm=2
CEM 3 Contact Input 9 Activation Delay
GG
0688
Uint32 4
R W Second
0 - 300
CEM 3 Contact Input
10
Contact Recognition
GG
0690
Uint32 4
R W n/a
Always=0
Engine Running=1
CEM 3 Contact Input
10
Alarm Configuration
GG
0692
Uint32 4
R W n/a
Status Only=0
Pre-Alarm=1
Alarm=2
CEM 3 Contact Input
10
Activation Delay
GG
0694
Uint32 4
R W Second
0 - 300
CEM 4 Contact Input 1 Contact Recognition
GG
0696
Uint32 4
R W n/a
Always=0
Engine Running=1
CEM 4 Contact Input 1 Alarm Configuration
GG
0698
Uint32 4
R W n/a
Status Only=0
Pre-Alarm=1
Alarm=2
CEM 4 Contact Input 1 Activation Delay
GG
0700
Uint32 4
R W Second
0 - 300
CEM 4 Contact Input 2 Contact Recognition
GG
0702
Uint32 4
R W n/a
Always=0
Engine Running=1
CEM 4 Contact Input 2 Alarm Configuration
GG
0704
Uint32 4
R W n/a
Status Only=0
Pre-Alarm=1
Alarm=2
CEM 4 Contact Input 2 Activation Delay
GG
0706
Uint32 4
R W Second
0 - 300
CEM 4 Contact Input 3 Contact Recognition
GG
0708
Uint32 4
R W n/a
Always=0
Engine Running=1
CEM 4 Contact Input 3 Alarm Configuration
GG
0710
Uint32 4
R W n/a
Status Only=0
Pre-Alarm=1
Alarm=2
CEM 4 Contact Input 3 Activation Delay
GG
0712
Uint32 4
R W Second
0 - 300
CEM 4 Contact Input 4 Contact Recognition
GG
0714
Uint32 4
R W n/a
Always=0
Engine Running=1
CEM 4 Contact Input 4 Alarm Configuration
GG
0716
Uint32 4
R W n/a
Status Only=0
Pre-Alarm=1
Alarm=2
CEM 4 Contact Input 4 Activation Delay
GG
0718
Uint32 4
R W Second
0 - 300
CEM 4 Contact Input 5 Contact Recognition
GG
0720
Uint32 4
R W n/a
Always=0
Engine Running=1
CEM 4 Contact Input 5 Alarm Configuration
GG
0722
Uint32 4
R W n/a
Status Only=0
Pre-Alarm=1
Alarm=2
CEM 4 Contact Input 5 Activation Delay
GG
0724
Uint32 4
R W Second
0 - 300
CEM 4 Contact Input 6 Contact Recognition
GG
0726
Uint32 4
R W n/a
Always=0
Engine Running=1
CEM 4 Contact Input 6 Alarm Configuration
GG
0728
Uint32 4
R W n/a
Status Only=0
Pre-Alarm=1
Alarm=2
CEM 4 Contact Input 6 Activation Delay
GG
0730
Uint32 4
R W Second
0 - 300
CEM 4 Contact Input 7 Contact Recognition
GG
0732
Uint32 4
R W n/a
Always=0
Engine Running=1
CEM 4 Contact Input 7 Alarm Configuration
GG
0734
Uint32 4
R W n/a
Status Only=0
Pre-Alarm=1
Alarm=2
CEM 4 Contact Input 7 Activation Delay
GG
0736
Uint32 4
R W Second
0 - 300
CEM 4 Contact Input 8 Contact Recognition
GG
0738
Uint32 4
R W n/a
Always=0
Engine Running=1
CEM 4 Contact Input 8 Alarm Configuration
GG
0740
Uint32 4
R W n/a
Status Only=0
Pre-Alarm=1
Alarm=2
CEM 4 Contact Input 8 Activation Delay
GG
0742
Uint32 4
R W Second
0 - 300