Default Register Table
DGC-2020HD Modbus
™ Protocol
Name
Description
Group Register Type Bytes R/W
Unit
Range
Time
DST End Month
GG
0186
Uint32 4
R W n/a
January=0
February=1
March=2
April=3
May=4
June=5
July=6
August=7
September=8
October=9
November=10
December=11
Time
DST End Day
GG
0188
Uint32 4
R W n/a
1 - 31
Time
DST End Week Of Month
GG
0190
Uint32 4
R W n/a
First=0
Second=1
Third=2
Fourth=3
Last=4
Time
DST End Day Of Week
GG
0192
Uint32 4
R W n/a
Sunday=0
Monday=1
Tuesday=2
Wednesday=3
Thursday=4
Friday=5
Saturday=6
Time
DST End Hour
GG
0194
Uint32 4
R W n/a
0 - 23
Time
DST End Minute
GG
0196
Uint32 4
R W n/a
0 - 59
Time
DST Bias Hours
GG
0198
Int32
4
R W n/a
-23 - 23
Time
DST Bias Minutes
GG
0200
Int32
4
R W n/a
-59 - 59
Time
Twelve-Hour Mode
GG
0202
Uint32 4
R W n/a
12 Hour Mode=0
24 Hour Mode=1
Time
Date Format
GG
0204
Uint32 4
R W n/a
YYYY-MM-DD=0
MM-DD-YYYY=1
DD-MM-YYYY=2
Unit Information
Style Number
GG
0206
String 32
R W n/a
0 - 32
Unit Information
Serial Number
GG
0222
String 32
R W n/a
0 - 32
Load Detection
EPS Threshold
GG
0238
Uint32 4
R W Percent
3 - 10
Load Detection
Low-Line Scale
GG
0240
Float
4
R W n/a
0.001 - 3
Load Share Settings
System Type
GG
0242
Uint32 4
R W n/a
Single Generator=0
Multiple
Generator=1
Load Share Settings
Enable Comms Fail Pre Alarm
GG
0244
Uint32 4
R W n/a
Disabled=0
Enabled=1
Auto Restart
Auto Restart Enable
GG
0246
Uint32 4
R W n/a
No=0
Yes=1
Auto Restart
Auto Restart Timeout Sec
GG
0248
Uint32 4
R W Second
30 - 1800
Auto Restart
Auto Restart Attempts
GG
0250
Uint32 4
R W n/a
1 - 10
ECU Config
CANBus Enabled By User
GG
0252
Uint32 4
R W n/a
Disabled=0
Enabled=1
ECU Config
DTC Enable
GG
0254
Uint32 4
R W n/a
Disabled=0
Enabled=1
ECU Config
J1939 Source Address
GG
0256
Uint32 4
R W n/a
1 - 253
ECU Config
ECU Control Output
GG
0258
Uint32 4
R W n/a
FL CNTCT=0
PS CNTCT=1
ECU Config
Pulsing Enable
GG
0260
Uint32 4
R W n/a
Disabled=0
Enabled=1
ECU Config
ECU Settling Time
GG
0262
Uint32 4
R W Millisecond 5500 - 30000
ECU Config
ECU Pulse Cycle Time
GG
0264
Uint32 4
R W Minute
1 - 60
ECU Config
ECU Disconnect Time
GG
0266
Uint32 4
R W Second
1 - 60
ECU Config
ECU Connect Time
GG
0268
Uint32 4
R W Second
1 - 60
ECU Config
CAN Bus Eng Ctrl Param Transmit Enable GG
0270
Uint32 4
R W n/a
Disabled=0
Enabled=1
ECU Config
Requested MTU SMC Eng Operating
Mode
GG
0272
Uint32 4
R W n/a
1 - 2
ECU Config
SPN Conversion Method
GG
0274
Uint32 4
R W n/a
1 - 4
ECU Config
Voltage Regulator CANbus type
GG
0276
Uint32 4
R W n/a
None=0
Marathon=1
Basler=2
J1939=3
ECU Config
Voltage Regulator Primary Voltage
Setpoint
GG
0278
Uint32 4
R W Decivolt
1000 - 6000
ECU Config
Voltage Regulator Alternate Voltage
Setpoint
GG
0280
Uint32 4
R W Decivolt
1000 - 6000
ECU Config
Voltage Regulator Voltage Adjust
Bandwidth
GG
0282
Uint32 4
R W Centivolt
0 - 3000
ECU Config
Voltage Regulator Field Current
GG
0284
Uint32 4
R W Milliamp
0 - 3000000
ECU Config
Voltage Regulator Primary
Underfrequency Knee
GG
0286
Uint32 4
R W Decihertz
400 - 700