Switch # show interface GigabitEthernet 1/1 switchport

Name: GigabitEthernet 1/1

Administrative mode: access

Access Mode VLAN: 1

Trunk Native Mode VLAN: 1

Administrative Native VLAN tagging: disabled

Allowed VLANs: 1-4095

Hybrid port configuration

-------------------------

Port Type: C-Port

Acceptable Frame Type: All

Ingress filter: Disabled

Egress tagging: All except-native

Hybrid Native Mode VLAN: 1

Hybrid VLANs Enabled: 1-4095

4.21.24 show interface veriphy

Command:

show interface veriphy

show

Show running system information

interface

Interface status and configuration

veriphy

Run cable diagnostics and show result.

Default:

N/A

Usage Guide:

To display the result of Cable Diagnostics.

Example:

To display the result of Cable Diagnostics for interface GigabitEthernet 1/1.

Switch # show interface GigabitEthernet 1/1 veriphy

Starting VeriPHY - Please wait

Interface Pair

A Length P air B, Length

---------------------- ------ ------ ------- -------

GigabitEthernet 1/1 OK 3 OK 3

Pair C L ength Pair D Length