Chapter 2 CONSOLE CLI MANAGEMENT

2.1 Terminal Setup

To configure th e system, connect a ser ial cable to a COM port on a PC or note book computer and to RJ-45 t ype of serial
(console) port of the Managed Switch.

Figure 2-1

Managed Switch Console Connectivity

The console port of the Man aged S witch is a RJ-45 t ype, RS-23 2 seri al port con nector. It is an inter face for con necting a

terminal directly. Through the console port, it provides rich diagnostic information including IP Address setting, factory reset, port

management, link st atus and system setting. Users can us e the attached RS-232 c able in the p ackage and connect to the

console port on the d evice. After the c onnection, users can ru n any terminal emulation program (Hyper Terminal, ProComm

Plus, Telix, Winterm and so on) to enter the startup screen of the device.

NS4702-24P-4S-4X Front Panel

Figure 2-2:

Front Panel of NS4702-24P-4S-4X

A terminal pr ogram is re quired to make the software connection to th e Managed Switch. Windows' Hyper Terminal program
may be a good choice. The Hyper Terminal can be accessed from the Start menu.

1. Click

START

, then Programs, Accessories and then Hyper Terminal.

2.

When the following screen appears, make sure that the COM port should be configured as:

Baud

: 115200

Data bits

: 8

Parity

: None

Stop bits

: 1

Flow control

: None

Console port