Chapter 2 console cli management, 1 terminal setup – Interlogix NS4702-24P-4S-4X Command Line Guide User Manual
Page 24
-24-
Chapter 2 CONSOLE CLI MANAGEMENT
2.1 Terminal Setup
To configure th e system, connect a ser ial cable to a COM port on a PC or note book computer and to RJ-45 t ype of serial
(console) port of the Managed Switch.
Figure 2-1
Managed Switch Console Connectivity
The console port of the Man aged S witch is a RJ-45 t ype, RS-23 2 seri al port con nector. It is an inter face for con necting a
terminal directly. Through the console port, it provides rich diagnostic information including IP Address setting, factory reset, port
management, link st atus and system setting. Users can us e the attached RS-232 c able in the p ackage and connect to the
console port on the d evice. After the c onnection, users can ru n any terminal emulation program (Hyper Terminal, ProComm
Plus, Telix, Winterm and so on) to enter the startup screen of the device.
NS4702-24P-4S-4X Front Panel
Figure 2-2:
Front Panel of NS4702-24P-4S-4X
A terminal pr ogram is re quired to make the software connection to th e Managed Switch. Windows' Hyper Terminal program
may be a good choice. The Hyper Terminal can be accessed from the Start menu.
1. Click
START
, then Programs, Accessories and then Hyper Terminal.
2.
When the following screen appears, make sure that the COM port should be configured as:
Baud
: 115200
Data bits
: 8
Parity
: None
Stop bits
: 1
Flow control
: None
Console port