beautypg.com

20 evc l2cp discard(gg), 21 evc l2cp forward(gg) – Interlogix NS4702-24P-4S-4X Command Line Guide User Manual

Page 106

background image

-106-

Usage Guide:

To configure EVC DEI mode

Example:

To configure EVC DEI mode (Colored) for GigabitEthernet X/X.

Switch# configure terminal

Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # evc dei colored

4.2.65.20 evc l2cp discard(GG)

Command:

evc l2cp discard

evc Ethernet Virtual Connections

l2cp

Setup L2CP forwarding

discard

Discard L2CP frames

Select BPDU addresses (0-15) and GARP addresses (16-31)

Default:

N/A

Usage Guide:

To configure policy ID of L2CP discard

Example:

To configure policy ID 1 of L2CP discard for GigabitEthernet X/X.

Switch# configure terminal

Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # evc l2cp discard 1

4.2.65.21 evc l2cp forward(GG)

Command:

evc l2cp forward

evc Ethernet Virtual Connections

l2cp

Setup L2CP forwarding

forward

Allow forwarding of L2CP frames