Switch# configure terminal
Switch (config)# mep 1 tst 3 dei mep-id 2 sequence one-zero rate 10 size 68

4.2.144 mep up

Command:

mep [mip]

up domain { port | evc | vlan } [ vid ] flow level

interface

mep Maintenance Entity Point

The MEP instance number.

mip

This MEP instance is a half-MIP

up

This MEP is a Up-MEP

domain

The domain of the MEP

evc

This MEP is a EVC domain MEP.

port

This MEP is a Port domain MEP.

vlan

This MEP is a VLAN domain MEP.

flow

The flow instance that the MEP is related to.

The flow instance number when not in the port domain.

vid

In case the MEP is a port Up-MEP or a EVC customer MIP the VID must be given.

The port Domain MEP VID. This is required for a Port Up-MEP.

Default:

None

Usage Guide:

To configure Up-MEP of MEP.

Example:

To configure Up-MEP of MEP 2 as below table

Switch# configure terminal
Switch (config)# mep 2 up domain port vid 1 flow 1 level 2 interface GigabitEthernet

1/1