beautypg.com

125 switchport hybrid acceptable-frame-type – Interlogix NS4702-24P-4S-4X Command Line Guide User Manual

Page 163

background image

-163-

Default:

1

Usage Guide:

To remove forbidden VLAN ID for specific interface

Example:

To remove forbidden VLAN ID (5) for GigabitEthernet X/X

Switch# configure terminal

Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # switchport forbidden vlan remove 5

4.2.65.125 switchport hybrid acceptable-frame-type

Command:

switchport hybrid acceptable-frame-type all | tagged | untagged

switchport

Switching mode characteristics

hybrid

Change PVID for hybrid port

acceptable-frame-type

Set acceptable frame type on a port.

all

Allo w all frames

tagged

Allow only tagged frames

untagged

Allow only untagged frames

Default:

All

Usage Guide:

To configure acceptable-frame-type of Hybrid VLAN for specific interface

Example:

To configure acceptable-frame-type (tagged) of Hybrid VLAN for GigabitEthernet X/X

Switch# configure terminal

Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # switchport hybrid acceptable-frame-type tagged