49 lacp timeout, 50 lldp cdp-aware – Interlogix NS4702-24P-4S-4X Command Line Guide User Manual
Page 121
-121-
4.2.65.49 lacp timeout
Command:
lacp timeout fast | slow
lacp
Enable LACP on this interface
timeout
The period between BPDU transmissions
fast
T ransmit BPDU each second (fast timeout)
slow
Transmit BPDU each 30th second (slow timeout)
Default:
Fast
Usage Guide:
To configure LACP timeout type for specific interface
Example:
To enable LACP timeout type (slow) for GigabitEthernet X/X
Switch# configure terminal
Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # lacp timeout slow
4.2.65.50 lldp cdp-aware
Command:
lldp cdp-aware
lldp
LLDP configurations
cdp-aware
Configures if the interface shall be CDP aware (CDP discovery information is added to the LLDP neighbor
table)
Default:
Passive
Usage Guide:
To configure MIB variable retrieve local info or remote info of LLDP for specific interface
Example:
To configure MIB variable retrieve (local info) of LLDP for GigabitEthernet X/X
Switch# configure terminal
Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # lldp cdp-aware