beautypg.com

49 lacp timeout, 50 lldp cdp-aware – Interlogix NS4702-24P-4S-4X Command Line Guide User Manual

Page 121

background image

-121-

4.2.65.49 lacp timeout

Command:

lacp timeout fast | slow

lacp

Enable LACP on this interface

timeout

The period between BPDU transmissions

fast

T ransmit BPDU each second (fast timeout)

slow

Transmit BPDU each 30th second (slow timeout)

Default:

Fast

Usage Guide:

To configure LACP timeout type for specific interface

Example:

To enable LACP timeout type (slow) for GigabitEthernet X/X

Switch# configure terminal

Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # lacp timeout slow

4.2.65.50 lldp cdp-aware

Command:

lldp cdp-aware

lldp

LLDP configurations

cdp-aware

Configures if the interface shall be CDP aware (CDP discovery information is added to the LLDP neighbor

table)

Default:

Passive

Usage Guide:

To configure MIB variable retrieve local info or remote info of LLDP for specific interface

Example:

To configure MIB variable retrieve (local info) of LLDP for GigabitEthernet X/X

Switch# configure terminal

Switch (config)# interface GigabitEthernet X/X
Switch (config-if) # lldp cdp-aware