Event log results parameters, Event log results, Event log results parameters on – Rockwell Automation 1404-M4_M5_M6_M8 Powermonitor 3000 User Manual, Firmware rev. 3.0 or LATER User Manual
Page 229
Publication 1404-UM001F-EN-P - November 2009
229
Powermonitor 3000 Data Tables Appendix A
Event Log Results Parameters
CSP File No.
N29
Remote I/O BT
21
CIP Assy. Inst.
34
No. of Elements
14, 17, or 18 (see table)
User Configurable No
Data Type
Integer
Data Access
Read only
PM3000 Type
See table
Event Log Results
Element
No.
Modbus
Address
M4
M5
M
6
M
8
Element Name
Range
Comment
0
30901
•
• •
Reserved
0
Returns 0
1
30902
•
• •
Internal identifier
0 …32768
Refer to Reading Data from the Event Log
by Using Communication on page 147
2
30903
•
• •
Timestamp of event;
Year
Month/day
Hour/minute
Second/hsec
1998…2097
Refer to Expressing Data in Data Tables on
page 82
3
30904
•
• •
0101…1231
4
30905
•
• •
0000…2359
5
30906
•
• •
0000…5999
6
30907
•
• •
Event type
0…19
Refer to List of Event Types Parameters
7
30908
•
• •
Event code
-
Refer to Reading Data from the Event Log
by Using Communication on page 147
8
30909
•
• •
Setpoint type
0…52
9
30910
•
• •
Setpoint evaluation condition
0…5
10
30911
•
• •
Setpoint level
integer
exponent
0…9999
11
30912
•
• •
-21…21
12
30913
•
• •
Setpoint action/release delay
0…3600 (M4, M5)
0…30,000 (M6, M8)
13
30914
•
• •
Setpoint action
0…32 (M4, M5)
0…43 (M6, M8)
14
30915
• •
Sustain limit timer
integer
exponent
0…9999
15
30916
• •
-4…21
16
30917
• •
Capture identifier
0…999
17
30918
•
Reserved
0
Returns 0