Appendix A Powermonitor 3000 Data Tables
Summary of Powermonitor 3000 Data Tables for all Communication Options
Data Table Name and Description
(1)
Dat
a
Acc
e
ss
Index
ed
Reads
(3)
Fi
le No.
(4
)
(DF
1,
CSP
)
Remo
te I/
O
BT Size
As
sy
Instance
(CIP
, DNet
)
Modbus
Starting
Add
ress
(6
)
No. of
Elements
Applies to
Config
ur
-
able
Refer to
Page
M4, M5
M6
M8
Remote I/O, DeviceNet, EtherNet/IP and
ControlNet I/O Messaging Parameters
R/W
-
-
I/O
1,2
-
-
(7)
• • •
•
(7)
R
N9
10
3
30001
6
• • •
Basic Device Configuration Parameters
R/W
F10
20
4,5
40001
8 or 9
(8)
• • •
R/W
N11
12
6,7
40101
8
• • •
Advanced Device Configuration Parameters
R/W
N12
26
8,9
40201
26
• • •
Native Communication Configuration Parameters
R/W
N13
11
10,11
40301
10
(9)
• • •
Optional Communication Configuration Parameters
R/W
N14
24
12,13
40401
20
• • •
Metering Voltage, Current, and Frequency Result
Parameters
R
F15
38
14
30101
14
• • •
Metering Sequence Voltage, and Current Results
Parameters
R
F16
27
15
30201
11
• • •
Metering Power Results Parameters
R
F17
31
16
30301
13
• • •
Metering Demand Results Parameters
R
F18
25
17
30401
10
• • •
Metering Power Factor Results Parameters
R
F19
33
18
30501
13
• • •
Metering Real and Apparent Energy Results
Parameters
R/W
N20
29
19,20
40501
23
• • •
Metering Reactive Energy and Amp-hour Results
Parameters
R/W
N21
30
21,22
40601
23
• • •
Selftest/Diagnostic Results Parameters
R
N22
36
23
30601
27
• • •
DF1 PCCC Diagnostic Status Reply Parameters
R
(5)
-
-
-
-
• • •
Setpoint Setup/Read-back Select and Status
Parameters
R/W
•
N23
22
24,25
40701
16
• • •
Trend Log Configuration/Read-back Record Select
Parameters
R/W
N24
34
26,27
40801
26
• • •
R
•
F25
48
28
30701
14 or 22
(10)
• • •
•
Min/Max Log Configuration/Read-back Select
Parameters
R/W
N26
13
29,30
40901
9
• • •
Min/Max Log Results Parameters
R
•
F27
28
31
30801
11
• • •
Event Log Configuration/Read-back Record Select
Parameters
R/W
N28
9
32,33
41001
6
• • •
R
•
N29
21
34
30901
14,17,18
(11)
• • •
User-configured Table Setup Parameters
R/W
N30
35
35,36
41101
26
• • •
User-configured Table Results Parameters
R
F31
62
37
31001
14 or 23
(12)
• • •
•
R
N32
4
38
31101
2
• • •
Harmonic Analysis Configuration/Read-back Select
Parameters
R/W
N33
14
39,40
41201
9
• • •
Harmonic Results; THD, Crest Factor, and More
Parameters
R
•
F34
23
41
31201
9 or 10
(13)
• • •
Harmonic Results; Odd Harmonics 1…21
Parameters
R
•
F35
39
42
-
14
• •
Harmonic Results; Odd Harmonics 23…41
Parameters
R
•
F36
40
43
-
14
• •
Harmonic Results; Even Harmonics 2…20
Parameters
R
•
F37
41
44
-
14
• •
Harmonic Results; Even Harmonics 22…40
Parameters
R
•
F38
42
45
-
14
• •
Oscillograph Configuration/Read-back Data Select
Parameters
R/W
N39
15
46,47
-
11
• •