Rockwell Automation 1404-M4_M5_M6_M8 Powermonitor 3000 User Manual, Firmware rev. 3.0 or LATER User Manual
Rockwell Automation Equipment
Table of contents
Document Outline
- 1404-UM001F-EN-P, Bulletin 1404 Powermonitor 3000 User Manual
- Important User Information
- Summary of Changes
- Table of Contents
- Preface
- 1 - Safety
- 2 - Product Description
- Master Module
- Display Module
- Performance Features
- Product Features of Powermonitor 3000 Module
- Communication Options
- Status Indicators
- Status Indicators All Powermonitor 3000 Models
- Native RS-485 Communication Only (catalog numbers ending in -000)
- RS-232 Optional Communication (catalog numbers ending in -232)
- Remote I/O Optional Communication (catalog numbers ending in -RIO)
- DeviceNet Optional Communication (catalog numbers ending in -DNT)
- EtherNet/IP Optional Communication (catalog numbers ending in -ENT)
- ControlNet Optional Communication (catalog numbers ending in -CNT)
- 3 - Powermonitor 3000 Unit Operations
- Metering Functionality
- Summary of Measurements
- Metering Accuracy Class
- Voltage, Current, and Frequency Metering
- Power and Power Factor Results
- Energy and Demand Results
- Display Module Functionality
- Commands
- Configuration by Using the Display Module
- Device Configurations Summary
- Network Demand/Time Configuration Summary
- Daylight Saving Time Configuration Summary
- Metering Update Rate
- Metering Update Rate Calculation Based on Model and Device Configuration
- Min and Max Metering Update Rate for Each Model
- Meter Update Rate with Factory Default Configuration
- 4 - Communication
- Configuring Communication
- Native Communication Configuration Summary
- Optional RS-232 Communication Configuration Summary
- Optional Remote I/O Port Configuration Summary
- Optional DeviceNet Communication Configuration Summary
- Optional Ethernet Communication
- Data Messaging Overview
- Data Messaging- application Considerations
- Modbus Error Codes
- Explicit Messaging
- DeviceNet Message Types
- DeviceNet Class Services
- DeviceNet Object Classes
- Protocol Selection Table
- Ethernet Message Types
- Parameter Selection Bitfield Value
- 5 - Setpoint Programming and Operation
- 6 - I/O Operations
- 7 - Data Logging
- 8 - Advanced Features
- A - Powermonitor 3000 Data Tables
- Summary of Powermonitor 3000 Data Tables for all Communication Options
- Remote I/O, DeviceNet, EtherNet/IP and ControlNet I/O Messaging Parameters
- Remote I/O Discrete Data Provided by Powermonitor (Remote I/O Input Data)
- Remote I/O Discrete Data Accepted by Powermonitor Units (Master Output Data)
- DeviceNet, EtherNet/IP, and ControlNet I/O Data Provided by Powermonitor Units (Scanner Input Data; Instance 1)
- DeviceNet, EtherNet/IP, and ControlNet I/O Data Accepted by Powermonitor Units (Scanner Output Data; Instance 2)
- Discrete Data Parameters
- Discrete Data
- Basic Device Configuration Parameters
- Basic Device Configuration
- Date and Time Parameters
- Date and Time
- Advanced Device Configuration Parameters
- Advanced Device Configuration
- Native Communication Configuration Parameters
- Native Communication Configuration
- Optional Communication Configuration Parameters
- Ethernet
- ControlNet
- Remote I/O
- DeviceNet
- RS-232
- Metering Voltage, Current, and Frequency Result Parameters
- Metering Voltage, Current, and Frequency Result
- Metering Sequence Voltage, and Current Results Parameters
- Metering Sequence Voltage, and Current Results
- Metering Power Results Parameters
- Metering Power Results
- Metering Demand Results Parameters
- Metering Demand Results
- Metering Power Factor Results Parameters
- Metering Power Factor Results
- Metering Real and Apparent Energy Results Parameters
- Metering Real and Apparent Energy Results
- Metering Reactive Energy and Amp-hour Results Parameters
- Metering Reactive Energy and Amp-hour Results
- Selftest/Diagnostic Results Parameters
- Selftest/Diagnostic Results
- DF1 PCCC Diagnostic Status Reply Parameters
- Setpoint Setup/Read-back Select and Status Parameters
- Setpoint Setup/Read-back Select and Status
- List of Setpoint Types Parameters
- List of Setpoint Types
- Setpoint Output Actions Parameters
- Setpoint Output Actions
- Trend Log Configuration/Read-back Record Select Parameters
- Trend Log Configuration/Read-back Record Select
- Trend Log Results Parameters
- Trend Log Results
- Min/Max Log Configuration/Read-back Select Parameters
- Min/Max Log Configuration/Read-back Select
- Min/Max Log Parameter List Parameters
- Min/Max Log Parameter List
- Min/Max Log Results Parameters
- Min/Max Log Results
- Event Log Configuration/Read-back Record Select Parameters
- Event Log Configuration/Read-back Record Select
- Event Log Results Parameters
- Event Log Results
- Status Error Codes
- List of Event Types Parameters
- List of Event Types
- User-configured Table Setup Parameters
- User-configured Table Setup
- User-configured Table Results Parameters
- User-configured Table Results
- Write Error Status Parameters
- Write Error Status
- Harmonic Analysis Configuration/Read-back Select Parameters
- Harmonic Analysis Configuration/Read-back Select
- Harmonic Results; THD, Crest Factor, and More Parameters
- Harmonic Results; THD, Crest Factor, and More
- Harmonic Results; Odd Harmonics 1…21 Parameters
- Harmonic Results; Odd Harmonics 1…21
- Harmonic Results; Odd Harmonics 23…41 Parameters
- Harmonic Results; Odd Harmonics 23…41
- Harmonic Results; Even Harmonics 2…20 Parameters
- Harmonic Results; Even Harmonics 2…20
- Harmonic Results; Even Harmonics 22…40 Parameters
- Harmonic Results; Even Harmonics 22…40
- Oscillograph Configuration/Read-back Data Select Parameters
- Oscillograph Configuration/Read-back Data Select
- Oscillograph Results Parameters
- Oscillograph Results
- Load Factor Log Configuration/Read-back Select Parameters
- Load Factor Log Configuration/Read-back Select
- Load Factor Log Results Parameters
- Load Factor Log Results
- Transient Analysis Configuration/Read-back Select Parameters
- Transient Analysis Configuration/Read-back Select
- Transient Analysis Metering Results Parameters
- Transient Analysis Metering Results
- Transient Capture Clear/Read-back Data Select Parameters
- Transient Capture Clear/Read-back Data Select
- Transient Capture Results Parameters
- Transient Capture Results
- Advanced Metering Configuration Parameters
- Advanced Metering Configuration
- Harmonic Results; Odd Harmonics 43…63 Parameters
- Harmonic Results; Odd Harmonics 43…63
- Harmonic Results; Even Harmonics 42…62 Parameters
- Harmonic Results; Even Harmonics 42…62
- Catalog Number and WIN Parameters
- Catalog Number and WIN
- Network Demand Sync and Time Configuration Parameters
- Network Demand Sync and Time Configuration
- Controller Command Parameters
- Controller Command
- Daylight Saving Time Configuration Parameters
- Daylight Saving Time Configuration
- Time of Use Register Configuration Parameters
- Time of Use Register Configuration
- Time of Use Records - Real Energy and Demand Parameters
- Time of Use Records - Real Energy and Demand
- Time of Use Records - Reactive Energy and Demand Parameters
- Time of Use Records - Reactive Energy and Demand
- Time of Use Records - Apparent Energy and Demand Parameters
- Time of Use Records - Apparent Energy and Demand
- Single Password Write Parameters
- Single Password Write
- Single Parameter Read Parameters
- Single Parameter Read
- Parameters for Trend Log and Configurable Table Parameters
- Parameters for Trend Log and Configurable Table
- B - Catalog Number Explanation
- C - Sample Applications
- Introduction
- System Clock Sample Applications
- Multiple Data Table Reads by Using DeviceNet
- Explicit Message Transfer Block
- Word M0:1.224
- Word M0:1.225
- Word M0:1.226
- Word M0:1.227
- Word M0:1.2278
- Word M0:1.229
- Data Files
- User-configured Data Table Setup by Using ControlLogix and EtherNet/IP Networks
- ControlLogix Tags Used
- Communicating with a SLC 5/05 (1747-L552) Controller and ControlNet Scanner (1747-SCNR), Unscheduled Messaging
- File N7:0
- N9 CIP
- PanelView Component HMI and EtherNet/IP Communication Network
- D - Technical Specifications
- E - Frequently Asked Questions
- Glossary
- Index
- Back Cover