Publication 1394-5.0 — May 2000

B-10

Interconnect and CE Diagrams

Figure B.6
Analog Servo System Interconnect Diagram

DRIVE O.K. RELAY

RATED AT 115VAC, 24VDC,

1A INDUCTIVE

(used for controller

fault logic)

COMMON

CONTACTOR ENABLE RELAY

RATED AT 115V AC, 24V DC,

1A INDUCTIVE

NOTES 3, 5

NOTES 3, 5

NOTE 13

NOTE 7

Analog Servo

Input Wiring Board

1394 ANALOG SERVO SYSTEM MODULE

DS1
SOLID GREEN = BUS UP, AXIS ENABLED
FLASHING GREEN = BUS UP, AXIS NOT ENABLED
FLASHING RED/GREEN = READY, BUS NOT UP
FLASHING RED = FAULT
SOLID RED = HARDWARE FAILURE

DC MINUS BUS

P1

NOTE 17

DC BUS POS.

DC BUS NEG.

NOTES 3, 6

24V AC/DC

or

120V AC,

50/60 HZ

STOP*

START*

CR1*

CR1*

CR1*

M1*

A1 VREF+
A1 VREF-
SHIELD
A1 TQREF+
A1 TQREF-
SHIELD

A3 VREF+
A3 VREF-
SHIELD
A3 TQREF+
A3 TQREF-
SHIELD

TB2

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19
20

TB1

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18
19
20

CONTROL POWER

& SIGNALS

A1 ENABLE

A3 ENABLE

A0 VREF+

A0 VREF-

SHIELD

A0 TQREF+

A0 TQREF-

SHIELD

A2 VREF+

A2 VREF-

SHIELD

A2 TQREF+

A2 TQREF-

SHIELD

A0 ENABLE

A2 ENABLE

24V ENABLE COM

CONTACTOR EN
CONTACTOR EN
DROK
DROK

NC

FAULT RESET

ANALOG OUT 1
ANALOG OUT 2

ANALOG COM

COM

CHASSIS

TO GROUND BAR IF

NOT GROUNDED ELSEWHERE

SLIDER INTERCONNECT

Refer to the

Wiring System, Axis, and Shunt Modules,

and Motors (for all systems) chapter

for ground jumper instructions.

EXTERNAL SHUNT

USER SUPPLIED 24V AC RMS OR

24V DC. (NON-POLARIZED)

THREE- PHASE INPUT

360-480V AC RMS

M1 *

W

U

PE

W1

W2

NOTE 1, 2

INPUT FUSING *

COL

DC+

V

22 KW INPUT POWER

B

TO BONDED SYSTEM

GROUND BAR

(Series A and B)

NOTE 25

24V FUSING *

OPTIONAL THREE-PHASE

INPUT NEUTRAL (Series C)

* INDICATES USER SUPPLIED COMPONENT

J10-1

J10-3

J11-2

EXTERNAL SHUNT

OPTIONAL

OPTIONAL THREE PHASE

INPUT NEUTRAL

USER SUPPLIED 24V AC RMS OR

24V DC. (NON-POLARIZED)

THREE- PHASE INPUT

360-480V AC RMS

M1 *

NOTE 1, 2

INPUT FUSING *

J10-2

J10-4

J11-1

J11-3

J1-1

J1-2

P10-1

P10-2

P10-3

P10-4

P11-1

P11-2

P11-3

5 AND 10 KW INPUT POWER

(Series C)

P1-1

P1-2

FACILITY
GROUND

A

24V FUSING *

SYSTEM MODULE

GROUND BAR

(Series C)

USER SUPPLIED 24V AC RMS OR

24V DC. (NON-POLARIZED)

OPTIONAL EXTERNAL SHUNT

THREE- PHASE INPUT

360-480V AC RMS

M1*

W

U

PE

W1

INT

W2

NOTE 1, 2

INPUT FUSING *

COL

DC+

V

5 AND 10 KW INPUT POWER

(Series A and B)

B

NOTE 17

24V FUSING *

TO BONDED SYSTEM GROUND BAR