Defining digital torque – Rockwell Automation 1326 Digital AC Multi-Axis Motion Control System User Manual User Manual
Page 133
![background image](/manuals/578607/133/background.png)
Publication 1394-5.0 — May 2000
Commissioning Your 1394 Analog Servo System
7-9
4. Press ENTER. The system records your choice and the cursor
moves to the top line.
5. Press ENTER. A message similar to the following appears:
6. Go to Defining Limits.
Defining Digital Torque
This procedure assumes that you have wired your 1394 Analog Servo
System and have completed the procedures in the following sections
of this chapter:
•
Removing and Re-Applying Power
•
Setting Up at the System Level
•
Setting Up Analog Test Points
•
Defining Your Motors
These procedures continue from step 4 of Defining a Reference for
Your Axes.
To define digital torque:
1. When the Ax:Mode Sel Dig Torq message appears, press
ENTER. A message similar to the following appears:
Note: The number on the left is the destination, while the
number on the right is the source.
2. Press SEL. The cursor moves to the bottom line.
3. Press either the up or down arrow until the parameter you want to
use for you digital torque appears.
4. Press ENTER. The system records your choice and the cursor
moves to the top line.
5. Press ENTER. A message similar to the following appears:
6. Go to Defining Limits.
Ax:Current Limit
+8.43 amps
Ax:Dig Torq Ref
<212> <---356
Ax:Current Limit
+8.43 amps