Finding Analog Servo System Faults

When a fault occurs for the Analog Servo version, a fault message
appears on the HIM.

Figure 9.1
HIM Fault Display

Each area on the diagram in Figure 9.1 has a significance:

Finding 9/440 Faults

Faults for the 9/440 appear on the second line of the operator panel.
There is also an error log that contains the most recent system faults.
To get to this error log screen:

1. At the main menu, press the continue softkey. The softkey menu

changes.

2. Press the {ERROR MESAGE} softkey. The error message screen

appears.

For more information on 9/440 system faults refer to the 9/Series
Integration and Maintenance Manual
(catalog 8520-6.2).

Fault Number

Fault Name

Hard Fault Indicator

Source of Fault

In this area:

This information appears:

Source of fault

The area in which the fault originated:
Ax0 = Axis module 0
Ax1 = Axis module 1
Ax2 = Axis module 2
Ax3 = Axis module 3
Sys = System module
CPU = The host CPU (hardware)
DSP = DSP CPU (hardware
Cus. = User action is the source of the fault
Hdw. = Drive hardware is the source of the fault

Fault name

An abbreviated message indicating a particular fault.

Hard fault indicator

If an exclamation point appears in this location, a hard
fault has occurred. You need to cycle drive power to
clear this type of fault.

Fault number

The number associated with the particular fault.