Publication 1394-5.0 — May 2000

8-14

Configuring Your 1394 Analog Servo System

[Language Sel]

Display language for text.

Parameter Numbers

4

Parameter Group

Linear List

Display Units

None

Parameter Type

Read/Write

Change While Running

Yes

Linkable

No

Default Value

0

English

Selections

0

English

[Ld/Lg Degrees]

If [Ld/Lg Freq] and [Ld/Lg Degrees] are set to
non-zero values, a lead/lag filter (one pole, one
zero) is additionally inserted into the feedback
path of the velocity loop. This filter can be used
to enhance the stability of the loop in the
presence of load resonances.
This parameter specifies the amount of phase
shift that occurs at the lead/lag center frequency.
A negative value specifies a lag, while a positive
value specifies a lead.
In most cases, this filter will not be needed.

Parameter Numbers

144, 145, 146, 147

Parameter Group

Vel Loop Tune

Display Units

degs

Parameter Type

Read/Write

Change While Running

Yes

Linkable

No

Minimum Value

-50 (lag) degs

Maximum Value

+50 (lead) degs

Default Value

0 degs

[Ld/Lg Freq]

This parameter specifies the center frequency of
the lead/lag filter in the velocity feedback path if
employed (see [Ld/Lg Degrees]. If set to zero,
the filter is disabled.
In most cases, this filter will not be needed.

Parameter Numbers

148, 149, 150, 151

Parameter Group

Vel Loop Tune

Display Units

Hz

Parameter Type

Read/Write

Change While Running

Yes

Linkable

No

Minimum Value

0 Hz

Maximum Value

200 Hz

Default Value

0 Hz

[Line Voltage]

This parameter selects input line voltage being
used. It affects motor velocity ratings and must
be configured prior to selecting motor types.

This value is set automatically in all Smart Power
22 kW systems and 5 and 10 kW (Series C or
later) systems.

Parameter Numbers

9

Parameter Group

Configuration, Setup

Display Units

None

Parameter Type

Read/Write

Change While Running

Yes

Linkable

No

Default Value

0

460 Volts AC

Selections

0

460 Volts AC

1

380 Volts AC

[Max Bandwidth]

After an auto tune, this parameter displays the
maximum system bandwidth that can be
achieved with the machine mechanics.

Parameter Numbers

304, 305, 306, 307

Parameter Group

ATune Config

Display Units

Hz

Parameter Type

Read Only

Linkable

No