4. locate the door panel latch(es) – Rockwell Automation 1326 Digital AC Multi-Axis Motion Control System User Manual User Manual

Page 193

background image

Publication 1394-5.0 — May 2000

Troubleshooting

9-27

3.

4. Locate the door panel latch(es).

Figure 9.8
1394 Shunt Modules Door Latches

5. Undo the door panel latch(es).

6. Open the door panel.

7. Locate the fuse holder.

Figure 9.9
Locating the Fuse Holder for the 1394 Shunt Modules

If your 1394-SR9A,
-SR9AF, -SR36A, or
-SR36AF shunt
module:

You need a:

Has the UL mark

Bussmann 600V DC 50A fuse
(FWP50A14F) or equivalent.

Does not have the UL
mark

Bussmann 600V DC 40/50A fuse
(170N2013), FWP50A22F or
equivalent.

1394-SR36A/36AF

1394 Digital Servo Controller

3600W Shunt Module

1394-SR9A/9AF

1394 Digital Servo Controller

300W Shunt Module

BULLETIN 1394 3600W SHUNT MODULE

ALLEN-BRADLEY

FOR USE WITH 1394-SJT22-X SYSTEM MODULE

CAT.

PART

SER.

INPUT DC

INPUT AC

BULLETIN 1394 300W SHUNT MODULE

ALLEN-BRADLEY

FOR USE WITH 1394-SJT22-X SYSTEM MODULE

CAT.

PART

SER.

INPUT DC

INPUT AC

Door Latch

Door Latch

Door Latch

1394-SR36A/36AF

1394-SR9A/9AF

Fuse Holder