4. locate the door panel latch(es) – Rockwell Automation 1326 Digital AC Multi-Axis Motion Control System User Manual User Manual
Page 193

Publication 1394-5.0 — May 2000
Troubleshooting
9-27
3.
4. Locate the door panel latch(es).
Figure 9.8
1394 Shunt Modules Door Latches
5. Undo the door panel latch(es).
6. Open the door panel.
7. Locate the fuse holder.
Figure 9.9
Locating the Fuse Holder for the 1394 Shunt Modules
If your 1394-SR9A,
-SR9AF, -SR36A, or
-SR36AF shunt
module:
You need a:
Has the UL mark
Bussmann 600V DC 50A fuse
(FWP50A14F) or equivalent.
Does not have the UL
mark
Bussmann 600V DC 40/50A fuse
(170N2013), FWP50A22F or
equivalent.
1394-SR36A/36AF
1394 Digital Servo Controller
3600W Shunt Module
1394-SR9A/9AF
1394 Digital Servo Controller
300W Shunt Module
BULLETIN 1394 3600W SHUNT MODULE