beautypg.com

4 k-controller, 6 configuration – JUMO 705010 mTRON T - Multichannel Controller Module Operating Manual User Manual

Page 80

background image

6 Configuration

80

6.9.4

K-Controller

The following functions are used in the plastics industry and require special skills. Configuration
should only be performed by specialists.

Boost function

The boost function is used to remove plastic residue in the tools during the production process.
The setpoint values of all heating zones are increased by a specific value for a specific amount
of time.
A setpoint value offset is also taken into account when the boost function is active.
The boost function is also active when setpoint value 2, 3, or 4 is active. If setpoint value
changeover occurs during the active boost phase, the boost function is aborted.

Setup dialog

Parameters

Parameter

Selection/settings

Description

Function

Without function

Boost function is switched off.

Absolute value

Setpoint value is increased by an abso-
lute value.

Percentage value

Setpoint value is increased by a per-
centage value.

Start signal

Digital selector (Inactive)

Signal for starting the boost function
(active in the case of a falling edge)

Value

-99999 to 0 to +99999

Amount by which the setpoint value is
increased (in K or % of setpoint value).

Boost period

00:00:00 to 99:59:59

Length of boost period (hh:mm:ss)

?