Page 76
Programming
74
900-0117-01-00 Rev C
System Information
The
System Information
screen contains a basic profile of the system.
Type of system (Off Grid, Grid Tied, Backup)
Nominal voltage of the battery bank
Array wattage (PV)*
Battery Amp-hours
Generator kW rating* and type
Inverter and charger kW rating*
*Used to scale the Home screen meter bars.
Figure 73
System Information Menu Item
Save / Restore Configuration
The
Save / Restore Configuration
allows for saving a configuration to an SD card after manual
programming is complete. It is also used to restore (or copy) a configuration from an SD card to an
identical system configuration.
Figure 74
Save / Restore Configuration Menu Item
Nominal Voltage – Allows for a battery bank with a
voltage of
12, 24, 36, 48 or 60 Vdc.
Battery Ah – Allows for total amp-hour rating of
the batteries from
25 Ah to 10,000 Ah.
Generator Type – Allows for an AC or DC
Generator, or
None.
Maximum Charger kW Rating – Allows for a
system with a total charger rating of
0 to 60 kW.
Set Points:
Type – Off Grid, Grid Tied, Backup. See page 33
for details on the respective Home screens.
Array Wattage – Allows for a PV Array (or arrays)
with a total wattage range of
0 to 50 kW.
Generator kW Rating – Allows for a generator
with a range of
0 to 250 kW.
Maximum Inverter kW Rating – Allows for an
inverter system with a wattage of
0 to 72 kW.