Charger hot key, Operation – Outback Power Systems MATE3 Owners Manual User Manual
Page 58
Operation
56
900-0117-01-00 Rev C
CHARGER Hot Key
The
CHARGER hot key displays the
Charger Status
screen. The
Charger Status
screen displays the
current charger mode, battery voltage, absorb and float voltage settings and timers. Soft key options
include starting or stopping the charger, which is a global command issued to all inverters in the system.
Other options include starting or the bulk or equalization charge functions, which are global commands
issued to all inverters and charge controllers in the system.
NOTE: The charging information displayed on this screen is for inverters only. In a multiple inverter
system, the master inverter controls this status. If an inverter or charge controller has a different charging
status from the master inverter, this screen will not display its status.
Figure 55
CHARGER Hot Key
IMPORTANT:
Equalization should only be performed on certain kinds of batteries under
specific conditions. Pressing the
recommendations and confirmations to ensure this function is not started
accidentally.
Soft Key Options:
Bulk
Charge screen to start a new charging cycle.
Equalize
Charge screen.
Charger Mode screen to enable or disable
the charger.
Screen Items:
Battery displays the uncompensated battery voltage.
Charger Control displays the mode of the charger.
Absorb displays the target voltage for the Bulk and
Absorption stages.
Float displays the target voltage for the Float stage.
If the timer is running to the right of either
Float or
Absorb, the system is in that charging stage.
CHARGER Hot Key