beautypg.com

Charger hot key, Operation – Outback Power Systems MATE3 Owners Manual User Manual

Page 58

background image

Operation

56

900-0117-01-00 Rev C

CHARGER Hot Key

The

CHARGER hot key displays the

Charger Status

screen. The

Charger Status

screen displays the

current charger mode, battery voltage, absorb and float voltage settings and timers. Soft key options
include starting or stopping the charger, which is a global command issued to all inverters in the system.
Other options include starting or the bulk or equalization charge functions, which are global commands
issued to all inverters and charge controllers in the system.

NOTE: The charging information displayed on this screen is for inverters only. In a multiple inverter
system, the master inverter controls this status. If an inverter or charge controller has a different charging
status from the master inverter, this screen will not display its status.

Figure 55

CHARGER Hot Key

IMPORTANT:

Equalization should only be performed on certain kinds of batteries under
specific conditions. Pressing the soft key will bring up several
recommendations and confirmations to ensure this function is not started
accidentally.

Soft Key Options:

returns to the Home screen.

advances to the

Bulk

Charge screen to start a new charging cycle.

advances to the

Equalize

Charge screen.

advances to the
Charger Mode screen to enable or disable
the charger.

Screen Items:

Battery displays the uncompensated battery voltage.

Charger Control displays the mode of the charger.

Absorb displays the target voltage for the Bulk and
Absorption stages.

Float displays the target voltage for the Float stage.

If the timer is running to the right of either

Float or

Absorb, the system is in that charging stage.

CHARGER Hot Key