Operation – Outback Power Systems MATE3 Owners Manual User Manual
Page 50

Operation
48
900-0117-01-00 Rev C
From the
FLEXnet DC
 screen, the 
.
Figure 40
Next Soft Key (with FLEXnet DC)
Figure 41
Stats Soft Key (with FLEXnet DC)
Screen Items:
Bat displays battery voltage, net current flow 
(positive or negative), battery temperature, and net 
amp-hour accumulation for that day. 
Min displays the lowest recorded battery voltage 
and SOC for that day, and the time each was 
recorded. 
Max displays the highest recorded battery voltage 
and SOC for that day, and the time each was 
recorded. 
Days Since Parms Met is the number of days since 
the last time the “fully charged” parameters were 
met (as defined on page 112). 
Soft Keys:
See Figure 41. 
three shunts on the battery monitor. 
See Figure 42. 
See Figure 42. 
Screen Items:
Cycle Charge Factor compares the amp-hours removed 
from the battery and those returned to the battery while 
charging. It displays the comparison as a percentage. This 
number can be compared against the programmed charge 
factor (see page 112) to judge battery charging efficiency. 
Cycle kWH Charge Efficiency compares the 
kilowatt-hours removed from the battery and those 
returned to the battery during all activity (such as float 
charging). It displays the comparison as a percentage. This 
number can be used to judge overall battery efficiency. 
Total Days at 100% displays the number of days since the 
batteries reached 100% SOC. If the batteries are not at 
100%, this will read 0. 
Total Days at 100% is computed by
the FLEXnet DC. It is a running total of the amount of time 
that the SOC's value is equal to 100%. This number is 
retained or continues to accumulate until reset by the user.
Lifetime kAH Removed accumulates the total amp-hours 
that were ever drained from the batteries. 
Soft Keys:
Total Days at 100%.
Lifetime kAH Removed.