background image

Installation

14

900-0117-01-00 Rev C

Location Considerations

The following information is important to consider when installing the OutBack MATE3:

 The MATE3 is intended for indoor installations only. Installing the MATE3 outdoors could expose it to damaging

environmental conditions. Such damage is not covered by the limited warranty.

 Readability of the display is affected by direct sunlight. It should be positioned about eye level for easier viewing

and access.

 The MATE3 voltage is less than 30 Vdc and is thus considered a “limited energy” circuit normally requiring no

conduit. Cable runs must be protected and runs must be in approved conduit when conditions require.
Consult the local inspector for specific installation requirements.

IMPORTANT:

Signal degradation can result if cable is run in conduit with AC wiring or in
other electrically “noisy” environments; these can affect the maximum length
the cable can run without incurring transmission errors.

Mounting Considerations

The MATE3 includes one 6-foot CAT5 cable. When working with CAT5 cables considering the following
best practices:

 CAT5 cable is not as strong as standard house wiring and must be handled carefully. Avoid kinking the cable or

tearing its outer sheathing.

 Use plastic standoff cable staples, J-hooks, or cable trays to support long runs of CAT5 cable. Do not splice cables.