DataLog Screen

The soft key shows accumulated daily amp-hour and watt-hour statistics, as well as maximum
current, wattage, and maximum and minimum voltage figures. These maintain a continuous daily log, up
to 128 days, which can be recalled. One day can be displayed at a time.

Figure 49

DataLog Screen

Soft Keys:

<+Day> advances the display forward by a
single day. If the display reads “Today”, it
does nothing.

<–Day> advances the display backward by a
single day and will display the selected date.

returns to the previous screen.

cycles through each device
connected to the network.

Current Date

Screen Items:

The upper left corner shows the date of the
selected DataLog screen. (The current DataLog
screen reads "Today.") To the right, this line also
displays the kilowatt-hours and amp-hours
accumulated that day.

Max Output displays the maximum current and
wattage recorded that day.

Absorb The amount of time the absorption timer
ran that day.

Float The amount of time the Float timer ran
that day.

High VOC displays the highest open-circuit
voltage (VOC) recorded that day.

Min Batt displays the lowest battery voltage
recorded that day.

Max Batt displays the highest battery voltage
recorded that day.