Programming

114

900-0117-01-00 Rev C

Reset FLEXnet DC to Factory Defaults

This menu allows the user to erase undesirable settings from the battery monitor and start over with the
values programmed at the factory. These values are listed in the FLEXnet DC Owner’s Manual.

Figure 141 Restoring the FLEXnet DC Monitor to Factory Default Settings

Press to return to
the

Battery Monitor menu.

To access the Reset to Factory Defaults menu:

1. Access

the

Main Menu as shown in Figure 71.

2. Select

the

Settings Menu. (This option may be

highlighted by default.)

3. Select

Battery Monitor in the device Settings Menu.

4. Select

the

Reset to Factory Defaults menu.

5.

Use the soft keys to select

No or Yes.

 If is selected, the screen returns to the

Battery Monitor menu. No changes will be
made to any settings.

 If is selected, the battery monitor's settings

will immediately change to the original factory
values. The screen will display the message
FLEXnet DC Restored to Factory Defaults.
A soft key will appear. Pressing this
key will return the screen to the

Battery Monitor

menu.

6.

After resetting the battery monitor to factory default
parameters:

 press the soft key or the Up

navigation key to return to the

Battery Monitor

menu, or

 press the Top navigation key to return to the

Settings Menu.