Operation

900-0117-01-00 Rev C

61

EVENTS Hot Key

The

EVENTS hot key displays the

Event History

screen. An event is defined as a change in status that

was externally imposed on a device on the HUB. A command to turn the inverter off or on, an automatic
generator start, or a loss of grid power are all defined as events. An event is not necessarily the sign of a
problem; however, the

Event History

screen logs all events for potential troubleshooting. In addition,

Errors, Warnings, and AGS Faults are accompanied by the Events LED.

 If the event is an inverter-based warning, the LED will flash.
 If the event is an inverter-based error, then the LED will be on solid. Errors are usually accompanied by the

inverter shutting down. Some warnings can become errors if left unattended.

 An AGS Fault is based in the MATE3. In this case, the LED will be on solid. This fault usually indicates an

automatic generator problem and is not accompanied by an inverter shutdown.

 Multiple events may occur simultaneously.

Soft key options include scrolling through each event and displaying details about that event to
determine if corrective action is required. Events may require acknowledgement before the EVENTS LED
will turn off. See page 150 for more information on troubleshooting event messages.

Event logs can be saved to an SC card. Refer to page 142 for instructions.

Figure 61

Using the EVENTS Hot Key

Soft Key Options:

returns to the Home screen.
highlights the next event in the list.
highlights the previous event in the list.
displays the details of the selected event, and prompting for acknowledgement, if necessary.

EVENTS Hot Key

Screen Items:

The left side of the screen lists the nature of the event.

The word

Fault will appear on the right side of the screen

if the event requires acknowledgement.

Error – Solid

Warning – Flashing

Screen Items:

If the and soft keys appear, either must
be pressed to acknowledge the event. Once
acknowledged, the EVENTS LED will turn off. An
acknowledgement (

ACKED) will replace the word Fault in

the

Event History screen.

Soft Key Options:

returns to the

Event History

screen.

will acknowledge one open event.
will acknowledge all open events.

See page 42 to view the

Inverter

Warnings and see page 43 for
the

Inverter Errors menus. See

the inverter Operator’s Manual for
descriptions of errors, warnings,
and other troubleshooting.

NOTE: Using the control wheel in the

Event

History Detail screen will display the detail
for the previous, or the next, event as listed
in the

Event History screen.

NOTE:

The control wheel will also scroll
up and down the list in the
Event History screen.