beautypg.com

Mppt, Charge controller settings, Figure 123 mppt – Outback Power Systems MATE3 Owners Manual User Manual

Page 107

background image

Charge Controller Settings

900-0117-01-00 Rev C

105

MPPT

The charge controller uses a maximum power point tracking (MPPT) algorithm which manipulates the
output of the PV array to harvest maximum wattage. Although this function is automatic, this menu
allows the user to adjust many of its parameters for special applications. See the charge controller
Owner’s Manual for more details on these parameters and their applications.

Figure 123 MPPT

Set Points:

MPPT Mode – Selects between Auto (which allows

automatic MPPT) and

U-Pick (which limits the maximum

power point tracking to a specified voltage).

U-Pick VOC – Adjusts the maximum power point tracking

limit, as a percentage of the array’s open-circuit voltage (V

OC

).

Wakeup VOC Change VDC – The controller monitors the

array V

OC

for a voltage increase sufficient for the controller to

leave Snooze mode and begin maximum power point
tracking. This setting adjusts the amount of voltage increase
for wakeup. (The charge controller Owner’s Manual refers to
this under the title “Wakeup Mode.”)

Wakeup VOC Change Time – The controller monitors the

array V

OC

and amperage to see if they are maintained long

enough for the controller to leave Snooze mode and begin
MPP tracking. (The voltage level must be at least 0.3 Vdc
above battery voltage; the current level is controlled by the
Snooze Mode Amps set point.) This setting adjusts the
minimum time for wakeup. (The charge controller Owner’s
Manual
refers to this under the title “Wakeup Mode.”)

Snooze Mode Amps – Adjusts the required current level

detected by the controller during the wakeup time
(see previous item).

MPP Range Minimum – Adjusts the lower limit of the

controller’s tracking algorithm. This can narrow the focus of
the initial MPPT process. The options are half the array’s V

OC

,

or the full V

OC

. (The Owner’s Manual refers to this under the

title “Mpp Range Limit %.”)

MPP Range Maximum – Adjusts the upper limit of the

controller’s maximum power point tracking algorithm. The
options are 80%, 85%, 90%, and 99% of the array’s VOC. (The
Owner’s Manual refers to this under the title “Mpp Range
Limit %.”)