beautypg.com

HP XP P9500 Storage User Manual

Page 451

background image

Key name

#1

Explanation

#2

Required or

optional?

Maximum

length

(characte

rs)

Required

for new

installatio

n

Required

for

upgrade

installati

on or re-

installati

on

on: Enable path health

checking (default).
off: Disable path health

checking.

path_health_check
_interval

Specify the interval at which

the path health check will be

performed in minutes.
You can specify a value from
1 to 1440. The default is 30.

Optional

Optional

4

auto_failback

Specify whether to enable

automatic failback for failed

paths by specifying either of

the following values:
on: Enable automatic failback

(default).
off: Disable automatic

failback.

Optional

Optional

3

auto_failback_int
erval

Specify the path status check

interval, which is the interval

between the end of the

previous check and the start

of the next check, in minutes.
You can specify a value from
1 to 1440. The default is 1.

Optional

Optional

4

intermittent_erro
r_monitor

#3#4

Specify whether to enable

intermittent error monitoring

by specifying either of the

following values:
on: Enable intermittent error

monitoring.
off: Disable intermittent

error monitoring (default).

Optional

Optional

3

intermittent_erro
r_monitor_interva
l

#4

Specify the interval for

intermittent error monitoring

in minutes.
You can specify a value from
1 to 1440. The default is 30.

Optional

Optional

4

intermittent_erro
r_monitor_number

#

4

Specify how many times an

error must occur to cause

Optional

Optional

2

Utility Reference