beautypg.com

The dlmgetras utility for collecting, The dlmgetras, And the information it collects, see – HP XP P9500 Storage User Manual

Page 417: The dlmgetras utility for collecting hdlm, Utility, see

background image

dlmvxexclude Utility for Assisting Creation of the VxVM Configuration File

on page 7-30

.

The installhdlm utility for installing HDLM
This utility performs a new installation, upgrade installation, or re-

installation of HDLM in unattended installation mode. For details on this

utility, see

The installhdlm Utility for Installing HDLM on page 7-32

. For

details on the procedure for performing an unattended installation, see

Performing a New Installation of HDLM (When Sun Cluster Is Not Being

Used) on page 3-55

,

Performing a New Installation of HDLM (When Sun

Cluster Is Being Used) on page 3-62

, or

Performing an Upgrade

Installation or Re-installation of HDLM on page 3-73

.

The removehdlm utility for removing HDLM
This utility removes HDLM in a Solaris 11 environment. For details about

the removehdlm utility, see

The removehdlm Utility for Removing HDLM

on page 7-41

.

Note

The utilities must be executed by a user with root permissions.

The DLMgetras Utility for Collecting HDLM Error Information

This utility collects information that is needed to analyze HDLM errors that

have occurred: information such as error logs, integrated trace files, trace

files, definition files, core files, system crash dump files, and libraries. The

collected information is archived in a file and saved to the directory that you

specified. The following files are output:

Name-of-the-directory-containing-a-system-crash-dump-file/system-

crash-dump-file
This file is a symbolic link file to a system crash dump file.

hbsa.tar.Z
This file contains compressed error information of the Hitachi Command

Suite products other than HDLM. This file is output only when using the

Hitachi Command Suite product that is the target for collecting error

information.

getras.tar.Z
This file contains compressed HDLM information and system information.

For details on the information that is stored in each file, see

List of Collected

Error Information on page 7-5

.

When you want to collect information other than that in

List of Collected Error

Information on page 7-5

, define the information to collect in a file for

defining the information to be collected. Information defined in a file for

defining the information to be collected is compressed into getras.tar.Z.

When the host is restarted, a part of the information that was collected by

the DLMgetras utility will be cleared. If an error occurs, immediately execute

this utility.

Utility Reference

7-3

Hitachi Dynamic Link Manager User Guide for Solaris

®

This manual is related to the following products: