beautypg.com

HP XP P9500 Storage User Manual

Page 316

background image

You can check the LU by using the format command. The following figure

shows an example of the format command. The shaded portion

represents an LU not managed by HDLM.

Figure 4-12 Example of executing the format command

12

.

Delete the device ID information for devices that do not exist.
Execute the following command:

# /usr/cluster/bin/scdidadm -C

13

.

Allocate the device ID.
Execute the following command:

# /usr/cluster/bin/scdidadm -r

Note

The following message might be output when the scdidadm -r

command is executed:

Unable to open '/dev/rdsk/c5t50060E80033A9902d2s2'

This message is output when a logical device file for a non-HDLM-

managed device exists. Delete the unnecessary logical device file. For

details, refer to the Sun Cluster documentation.

14

.

Notify the node of the most recent device ID information.
Execute the following command:

# /usr/cluster/bin/scdidadm -ui

15

.

Update the Sun Cluster global device namespace.
Execute the following command:

# /usr/cluster/bin/scgdevs

4-54

HDLM Operation

Hitachi Dynamic Link Manager User Guide for Solaris

®

This manual is related to the following products: