Path errors after boot processing completes, What to do for a program error, Path errors after boot processing completes -7 – HP XP P9500 Storage User Manual
Page 337: What to do for a program error -7
¢
The message output to the console by Solaris
¢
The message output to the console by the HBA driver
If an error occurs on one or more of the paths to the boot disk
HDLM outputs the KAPL08022-E message to the console, syslog, and
error log after the HDLM manager has started. Investigate the error and
take appropriate action after the HDLM manager has started, referring to
the following information:
¢
The KAPL08022-E message output by HDLM to the console, syslog,
and error log
¢
The message output to the console by Solaris
¢
The message output to the console by the HBA driver
When a path error occurs after the HDLM manager starts
On detection of a path error, HDLM immediately outputs the KAPL08022-E
message to the console, syslog, and error log. Therefore, even if boot
processing is cancelled at this stage due to errors on all paths to the boot
disk, investigate the error and take appropriate action, referring to the
following information:
¢
The KAPL08022-E message output by HDLM to the console, syslog,
and error log
¢
The message output to the console and syslog by Solaris
¢
The message output to the console and syslog by the HBA driver
Path Errors After Boot Processing Completes
Take the same action as for a local boot disk environment. For details, see
What To Do for a Path Error on page 5-3
.
What To Do for a Program Error
The following describes what to do to handle errors that occur in an HDLM
program. The following figure shows the troubleshooting procedure.
Troubleshooting
5-7
Hitachi Dynamic Link Manager User Guide for Solaris
®