HP XP P9500 Storage User Manual
Page 213
2
.
Enter a larger size in New Size(KB).
Set a new buffer size to fit the monitoring interval set in 5: Interval
Timer. The default value is 64. You can specify a value from 8 to 2048
(KB). Set this to a value smaller than the integrated trace file size set in
step 2 of
Changing the Size of Integrated Trace Files on page 3-145
recommended value is 256 for collecting an integrated trace.
If you do not want to change the buffer size, leave New Size(KB) blank,
type !, and then press the Enter key to return to the Hitachi Network
Objectplaza Trace Library setup menu.
3
.
Press the Enter key.
The new setting is applied and the Hitachi Network Objectplaza Trace
Library setup menu appears again.
4
.
In the Hitachi Network Objectplaza Trace Library setup menu, type 5 and
then press the Enter key.
A screen to set the monitoring interval appears. The current value is
displayed in Current Span(sec).
5
.
Enter a shorter interval in New Span(sec).
The default value is 10. You can specify a value from 1 to 300 (seconds).
The recommended value is 5 for collecting an integrated trace.
If you do not want to change the monitoring interval, leave New
Span(sec) blank, enter !, and then press the Enter key to return to the
Hitachi Network Objectplaza Trace Library setup menu.
6
.
Press the Enter key.
The new setting is applied and the Hitachi Network Objectplaza Trace
Library setup menu appears again.
Adjusting the Number of Messages to Be Output Per Monitoring
Interval
To adjust the number of messages to be output to fit a particular
monitoring interval:
1
.
In the Hitachi Network Objectplaza Trace Library setup menu, type 6, and
then press the Enter key.
Creating an HDLM Environment
3-147
Hitachi Dynamic Link Manager User Guide for Solaris
®