beautypg.com

HP XP P9500 Storage User Manual

Page 365

background image

-intvl error-monitoring-interval

Specify the monitoring interval for an intermittent error. Use a value

from 1 to 1440 minutes. The default is 30.
During intermittent error monitoring, if changes are made in the

settings of the intermittent error monitoring interval, the error count

and the elapsed time measured since monitoring starts are set to 0,

and monitoring starts by using the new settings.
Outside the duration of intermittent error monitoring, if changes are

made in the settings of the intermittent error monitoring interval, the

new settings take effect after the next time automatic failback

succeeds. Outside the duration of intermittent error monitoring, the

number of errors that determine an intermittent error is not counted

and this value is not changed.
The monitoring interval specified in this parameter is stored even

though specifying -iem off disables intermittent error monitoring.

Therefore, when you re-enable intermittent error monitoring and a

monitoring interval is not specified, error monitoring will be performed

by using the stored monitoring interval.

-iemnum number-of-times-error-is-to-occur

Specify the number of times the error is to occur. Valid values are

from 1 to 99. The default is 3.
During intermittent error monitoring, if you change the number of

times that the error is to occur, the error count and the elapsed time

measured since monitoring starts are reset to 0, and monitoring starts

by using the new settings.
Outside the duration of intermittent error monitoring, if you change

the number of times that the error is to occur, the new settings take

effect after the next time automatic failback succeeds. When

intermittent error monitoring is not being performed, the number of

errors that determine that an intermittent error has occurred is not

counted and this value is not changed.
The number of times that the error is to occur is stored in the system,

even when -iem off is specified and intermittent error monitoring is

disabled. Therefore, when you re-enable intermittent error monitoring

without specifying the number of times, the error monitoring will be

executed using the value stored in the system.

When the set -iem on operation is executed during error monitoring,

even though you do not change the conditions for intermittent error, the

number of errors and the time elapsed since the error monitoring starts

are reset to 0. Intermittent error monitoring will then resume with the

changed settings.
If you set the automatic failback function to off while intermittent error

monitoring is on, intermittent error monitoring will be disabled. Note,

however, that if you use the view -sys operation to display the HDLM

function configuration, Intermittent Error Monitor will be shown as on.

When the automatic failback function is returned to on, intermittent error

monitoring will once again be enabled.

Command Reference

6-25

Hitachi Dynamic Link Manager User Guide for Solaris

®

This manual is related to the following products: