Figure 18 configure date and time (manually), 18 configure date and time (manually), N in – HP StorageWorks 2.64 Director Switch User Manual
Page 60: Figure 17
Monitoring and managing the director
60
NOTE:
FICON management style only—An error results if periodic synchronization and clock
alert mode are enabled (see ”
Configuring the FICON management server
Figure 17
Configure Date and Time Periodic Synchronization dialog box
To immediately synchronize the director date and time with the HAFM appliance, be sure the
Periodic Date/Time Synchronization option is enabled and then click Sync Now.
NOTE:
If you enable the Periodic Date/Time Synchronization option and click
Activate, the time
will synchronize at the next update period.
To set the director with a specific date and time, make sure that the Periodic Date/Time
Synchronization field is not selected (see
). Enter the date and time, and then click
Activate.
Figure 18
Configure date and time (manually)
NOTE:
Use the range of 0 to 23 for hours. Use the range of 0 to 59 for minutes and seconds.
•
Set Online State—Displays the Set Online State dialog box. The dialog box displays the current
state (offline or online) and provides a button for changing the state.
CAUTION:
Before setting the director offline, warn administrators and users currently operating
attached devices that the director is going offline and that there will be a disruption of port
operation. Also, request that the devices affected by an interruption of data flow be set offline.