Figure 13 – HP StorageWorks 2.64 Director Switch User Manual
Page 55
Director Element Manager user guide
55
Figure 13
Monitoring hardware operation - Director 2/140 Hardware view
1.
Port card attention indicator—The yellow triangle status symbol ( ) indicates that the port card
is in a degraded state. This could indicate a problem with an individual port, such as a link
failure or service-required status. A yellow triangle could also indicate that a port is in
beaconing state. Open the Port Card view by double-clicking the port card to examine
individual port status. See ”
” on page 63 for details.
2.
Port card failure indicator—The blinking red and yellow diamond ( ) displayed on the port
card with the amber port card LED illuminated may indicate that the card has failed. This may
also indicate that an individual port has failed on the card. Open the Port Card view by
clicking the port card to examine individual port status. If an individual port has not failed, the
card is at fault.
See ”
” on page 63 for details on using the Port Card view. See ”
” on page 86 for details on port operating states and the status symbol and
indicator operation.
3.
CTP card failure indicator—The blinking red and yellow diamond ( ) on the CTP card with the
amber LED illuminated indicates that the card has failed.
4.
Active CTP card indicator—The green LED on a CTP card illuminates to indicate that the card is
active. Since the redundant CTP card on the left has failed, this CTP card has become the active
card. If both CTP cards are operational, no LEDs illuminate on the backup card, while the green
LED illuminates on the active CTP card.
5.
Power, system error, and unit beaconing indicators—The green and amber indicators on the far
right of the front bezel simulate the power and system error LEDs on the actual director bezel.
1
2
3
5
4
6
7
8
9