beautypg.com

Enabling and disabling switch binding, Figure 73 switch binding state change dialog box, 73 switch binding state change dialog box – HP StorageWorks 2.64 Director Switch User Manual

Page 161

background image

Director Element Manager user guide 161

After enabling Switch Binding, you prohibit devices and/or switches from connecting with director

or switch ports by removing them from the Membership List in the Switch Binding Membership List

dialog box. You allow connections by adding them to the Membership List. You can also add

detached nodes and switches.

Enabling and disabling switch binding

1.

Select Configure > Switch Binding > Change State from the Element Manager window. The

Switch Binding State Change dialog box appears, as shown in

Figure 73

.

Figure 73

Switch Binding State Change dialog box

2.

Perform one of the following steps:
• To disable Switch Binding (a check mark appears in the Enable Switch Binding check box),

click the Enable Switch Binding check box to remove the check mark, then click Activate.

• To enable Switch Binding (check mark is not in the Enable Switch Binding check box), click

the Enable Switch Binding check box to add a check mark. Go on to step 3 to set the

Connection Policy.

3.

Click one of the Connection Policy options.
• Restrict E_Ports—Select this option if you want to restrict connections from specific switches

to switch E_Ports. Switch WWNs can be added to the Switch Membership List to allow

connection and removed from the Membership List to prohibit connection. Devices are

allowed to connect to any F_Port.

• Restrict F_Ports—Select this option if you want to restrict connections from specific devices to

switch F_Ports. Device WWNs can be added to the Switch Membership List to allow

connection and removed from the Membership List to prohibit connection. Switches are

allowed to connect to any E_Port.

• Restrict All—Select this option if you want to restrict connections from specific devices to

switch F_Ports and switches to switch E_Ports. Device and switch WWNs can be added to

the Switch Membership List to allow connection and removed from the Membership List to

prohibit connection.

4.

Click Activate to enable the changes and close the dialog box.

5.

Edit the Switch Membership List through the Switch Binding Membership List dialog box to add

or remove switches and devices that are allowed to connect with the switch.

This manual is related to the following products: