HP StorageWorks 2.64 Director Switch User Manual
Page 188
Information and error messages
188
Cannot perform this operation
while the director is offline.
This operation cannot take place
while the director or switch is offline.
Configure the director or switch offline
through the Set Offline State dialog box
and then retry the operation.
Cannot retrieve current SNMP
configuration.
The director SNMP configuration
cannot be retrieved by the Element
Manager because the Ethernet link is
down or busy.
Retry the operation later. If the condition
persists, contact the next level of support.
Cannot retrieve diagnostics results.
Director diagnostic results cannot be
retrieved by the Element Manager
because the Ethernet link is down or
busy.
Retry the operation later. If the condition
persists, contact the next level of support.
Cannot retrieve information for
port.
Port information cannot be retrieved
by the Element Manager because the
Ethernet link is down or busy.
Retry the operation later. If the condition
persists, contact the next level of support.
Cannot retrieve port configuration.
The port configuration cannot be
retrieved by the Element Manager
because the Ethernet link is down or
busy.
Retry the operation later. If the condition
persists, contact the next level of support.
Cannot retrieve port statistics.
Port statistics cannot be retrieved by
the Element Manager because the
Ethernet link is down or busy.
Retry the operation later. If the condition
persists, contact the next level of support.
Cannot retrieve switch date and
time.
The director or switch date and time
cannot be retrieved by the Element
Manager because the Ethernet link is
down or busy.
Retry the operation later. If the condition
persists, contact the next level of support.
Cannot retrieve switch state.
The director or switch state cannot be
retrieved by the Element Manager
because the Ethernet link is down or
busy.
Retry the operation later. If the condition
persists, contact the next level of support.
Cannot run diagnostics on a port
that is failed.
Port diagnostics (loopback tests)
cannot be performed on a port that
has failed any previous diagnostic
(power-on diagnostic, online
diagnostic, or loopback test). The
amber LED associated with the port
illuminates to indicate the failed state.
Reset the port and perform diagnostics
again.
Cannot run diagnostics on an
active E-port.
Port diagnostics cannot be performed
on an active E-port.
Run diagnostics on an E-port only when it
is not active.
Table 10
Element Manager messages (continued)
Message
Description
Action