Director Element Manager user guide 119

• Tx Throughput—An alert will occur if the threshold set for transmit throughput is reached.
• Rx or Tx Throughput—An alert will occur if the threshold set for either receive or transmit

throughput is reached.

5.

Click Next. A new screen displays with additional parameters, as shown in

Figure 50

. The

name configured for the alert displays at the top of the screen.

NOTE:

Click Previous if you need to return to the previous screen.

Figure 50

New Threshold Alerts dialog box - second screen

6.

Enter a percentage from 1 through 100 for % utilization. When throughput reaches this

percentage of port capacity, a threshold alert will occur.

7.

Enter the amount of cumulative minutes in which the % utilization should exist during the

notification interval before an alert is generated. You can also click At any time if you want an

alert to occur whenever the set % utilization is reached. The valid range is from 1 to the interval

value set in

step 8

.

8.

Enter the interval in minutes in which throughput is measured and threshold notifications can

occur. The valid range is 5 minutes to 70,560 minutes.