Table 7 data default values, 7 data default values – HP StorageWorks 2.64 Director Switch User Manual
Page 147

Director Element Manager user guide 147
Factory-default values may vary, depending on the firmware release installed in your director. For
a list of values, refer to the HP StorageWorks Director 2/64 service manual for the Director 2/64
and the HP StorageWorks Director 2/140 service manual for the Director 2/140.
Table 7
Data default values
Configuration
Description
Default
Identification
Director Name
NULL string
Director Description
“Fibre Channel Director”
Director Contact
“End User Contact (please configure)”
Director Location
“End User Contact (please configure)”
Ports
Port Names
NULL strings
Port Blocked States
Unblocked
Extended Distance
(10–100 km)
Disabled
RX BB Credit
Disabled
LIN Alerts
Disabled
Port Address
Port number plus 4
Director Addressing
IP Address
10, mac[3], mac[4], mac[5] converted to word32
MAC addresses are set in hexadecimal; IP addresses in
decimal. A MAC address of 08 00 88 20 00 57 will be
reset to an IP address of 10.32.0.87.
Subnet Mask
255.0.0.0
Gateway Address
0.0.0.0
MAC Address
PROM value
Operating
Parameters
Preferred Domain ID
1
Buffer-to-Buffer Credit
16
R_A_TOV
10 seconds (100 tenths)
E_D_TOV
2 seconds (20 tenths)
Director Priority
254
Insistent Disabled
Rerouting Delay
Enabled
Domain RSCNs
Disabled
Suppress Zoning RSCNs
Disabled