beautypg.com

Clear system error light, Enable unit beaconing, Properties – HP StorageWorks 2.64 Director Switch User Manual

Page 25: Close, Configure menu, Identification

background image

Director Element Manager user guide

25

FRU
Click a serial crossbar (SBAR) card, control processor (CTP) card, port card, power supply module,

or cooling fan module in the Hardware view only and then select Product > FRU to display a menu

of options for the selected FRU. These options are the same menu options that display when you

right-click these components in the Hardware view. For details on these options, see the following

sections in

Using menu options

” on page 59:

Port Card menu

, page 61

CTP Card menu

, page 62

SBAR Card menu

, page 62

Clear System Error Light
Select this option to turn off the amber system error LED, located below the green power LED on the

director front bezel.
Enable Unit Beaconing
Click the Enable Unit Beaconing check box to toggle unit beaconing on or off. When the check box

has a check mark, unit beaconing is on, and the amber system error light on the director front

bezel blinks to help users locate the actual unit in an equipment room. When you click the check

box to remove the check mark, unit beaconing is disabled and the amber LED goes out. You can

only enable beaconing if there are no system errors (the system error light is off).
Properties
Select this option to display the Director Properties dialog box. This dialog box contains the

director name, description, location, and contact person configured through the Configure

Identification dialog box. Also included is other product information, as detailed under ”

Displaying

director information

” on page 58. You can also display this dialog box by double-clicking an area

in the Hardware view, away from a hardware component.
Close
Select this option to close the Element Manager window.

Configure menu

Select the Configure menu to display the following options. For detailed information on using these

options, see ”

Configuring the director

” on page 89.

Identification
Select this option to display the Configure Identification dialog box. Enter the following information

in this dialog box:

Name—Enter a product name. Note that you can set this name as the nickname for the

director’s WWN, using the Set Name as Nickname check box. The nickname then displays

instead of the WWN in Element Manager views.

Description—Enter a unique product description.

Location—Enter the product’s location.

Contact—Enter contact information, either a name, phone number, or e-mail address.

This manual is related to the following products: