a.
Add two connections to the mgmt 1131 network. When you finish entering the information
for a connection, click Add + to add this connection and reopen the dialog box so that
you can add the connections in the next step.
Value
Attribute
Ethernet
Device type
mgmt 1131
Network
2.5
(the default value)
Requested bandwidth
Auto
(the default value)
Port
For the first connection, select Primary. For the second connection, select
Secondary.
Boot
b.
Add two connections to the vmotion 1132 network. When you finish entering the
information for a connection, click Add +.
Value
Attribute
Ethernet
Device type
vmotion 1132
Network
2.5
(the default value)
Requested bandwidth
Auto
(the default value)
Port
For both connections, select Not bootable
Boot
c.
Add two connections to the prod networks network set. When you finish entering the
information for a connection, click Add +.
Value
Attribute
Ethernet
Device type
prod networks
Network
2.5
(the default value)
Requested bandwidth
Auto
(the default value)
Port
For both connections, select Not bootable
Boot
d.
Add one connection to the FC 1 network. Enter the information shown in the following
table, and then click Add + to add the connection and reopen the dialog box for the next
step.
Value
Attribute
Fibre Channel
Device type
FC 1
Network
2.5
(the default value)
Requested bandwidth
Auto
(the default value)
Port
Not bootable
Boot