beautypg.com

HP OneView User Manual

Page 254

background image

Possible cause and recommendation

Symptom

The server hardware or its iLO are powered-off or reset

In most cases, retrying the operation resolves the problem

The appliance cannot collect progress information from the iLO

In most cases, retrying the operation resolves the problem

A profile operation
timeout when
applying BIOS
settings

Invalid configuration

Auto-assignment for FlexNIC connections does not validate the following:

Bandwidth oversubscription on the physical port

Maximum networks (VLANs) on the physical port

Duplicate networks (VLANs) on the physical port

Manual assignment is required

Auto-assignment for
FlexNIC fails while
deploying
connections

31.15.2 What to do when you cannot apply the server profile

Possible cause and recommendation

Symptom

If you cannot apply the server profile because the PXE boot does not boot within the expected
amount of time, reset the iLO.

Cannot apply the
server profile

Verify the operational status of the server hardware

1.

Click Cancel to exit from the Create Server Profile screen.

2.

From the main menu, navigate to the Server Hardware screen.

3.

Find, and then select the server hardware.

Cannot verify the
status of the server
hardware

254 Troubleshooting