NORD Drivesystems BU0180 User Manual
Page 97
6 Parameterisation
BU 0180 GB-0914
Pre-series version
97
Parameter
{Factory setting}
Setting value / Description / Note
Device
Supervisor
Parameter
set
P400 ... P403
Output
frequency
P104
z.B. 0,0 V 2,5 V 5,0 V 10,0 V
P105
positive
P402
P403
Setpoint
voltage
Output
frequency
P104
z.B. 0,0 V 2,5 V 5,0 V 10,0 V
P105
positive
negative
P402
P403
Setpoint
voltage
P404
[-01]
[-02]
Analog input filter
(analog input filter)
S
10 ... 400 ms
{ all 100 }
Adjustable digital low-pass filter for the analog signal. Interference peaks are hidden, the reaction
time is extended.
[-01] =
Analog input 1
[-02] =
Analog input 2
P410
Min.freq. aux. setpt.
(Minimum frequency of auxiliary setpoints)
P
-400.0 ... 400.0 Hz
{ 0.0 }
The minimum frequency that can act on the setpoint via the auxiliary setpoints.
Auxiliary setpoints are all frequencies that are additionally delivered for further functions in the FI:
Frequency addition
Frequency subtraction
Auxiliary setpoints via BUS
PI process controller
PI controller
Multiplication
P411
Max.freq. aux. setpt.
(Maximum frequency of auxiliary setpoints
P
-400.0 ... 400.0 Hz
{ 50.0 }
The minimum frequency that can act on the setpoint via the auxiliary setpoints.
Auxiliary setpoints are all frequencies that are additionally delivered for further functions in the FI:
Frequency addition
Frequency subtraction
Auxiliary setpoints via BUS
PI process controller
PI controller
Multiplication