Display
Warning
Text in the ParameterBox
Cause
Remedy
Group
Details in
P700 [-02]
C008
8.0
Parameter loss
Warning: One of the cyclically saved messages such as
operating hours or enabling time could not be saved
successfully.
The warning disappears as soon as saving can be
successfully performed.
C012
12.1
Motor limit
"Motor switch-off limit"
Warning: 80% of the drive torque switch-off limit (P534 [-01])
has been exceeded.
Reduce load on motor
Set higher value in (P534 [-01]).
12.2
Generator limit
"Generator switch-off limit"
Warning: 80% of the generator torque switch-off limit
(P534 [-02]) has been exceeded.
Reduce load on motor
Set higher value in (P534 [-02]).
12.3
Torque limit
Warning: 80% of the limit from the potentiometer or the
setpoint source has been reached. P400 = 12
12.4
Current limit
Warning: 80% of the limit from the potentiometer or the
setpoint source has been reached. P400 = 14
12.5
Load limit
Warning due to overshooting or undershooting of
permissible load torques ((P525) … (P529)) for the time set
in (P528).
Adjust load.
Change limit values ((P525) ... (P527)).
Increase delay time (P528).