beautypg.com

NORD Drivesystems BU0180 User Manual

Page 149

background image

7 Status messages

BU 0180 GB-0914

Pre-series version

149

Display

Warning

Text in the ParameterBox

Cause

Remedy

Group

Details in
P700 [-02]

C008

8.0

Parameter loss

Warning: One of the cyclically saved messages such as
operating hours or enabling time could not be saved
successfully.
The warning disappears as soon as saving can be
successfully performed.

C012

12.1

Motor limit
"Motor switch-off limit"

Warning: 80% of the drive torque switch-off limit (P534 [-01])
has been exceeded.

Reduce load on motor

Set higher value in (P534 [-01]).

12.2

Generator limit
"Generator switch-off limit"

Warning: 80% of the generator torque switch-off limit
(P534 [-02]) has been exceeded.

Reduce load on motor

Set higher value in (P534 [-02]).

12.3

Torque limit

Warning: 80% of the limit from the potentiometer or the
setpoint source has been reached. P400 = 12

12.4

Current limit

Warning: 80% of the limit from the potentiometer or the
setpoint source has been reached. P400 = 14

12.5

Load limit

Warning due to overshooting or undershooting of
permissible load torques ((P525) … (P529)) for the time set
in (P528).

Adjust load.

Change limit values ((P525) ... (P527)).

Increase delay time (P528).