beautypg.com

NORD Drivesystems BU0180 User Manual

Page 103

background image

6 Parameterisation

BU 0180 GB-0914

Pre-series version

103

Value Function

Description

Signal

74 ²

Left block+ Fast

"Block left rotation + emergency
stop"

As for setting 32, however coupled to the function "Fast Stop".

Low

75

Dig.out. 2 man/auto set

"Set digital output 2 manually /
automatically"

As for function 67, however for digital output 2

High

76

Dig.out. 2 man. set

"Set digital output 2 manually"

As for function 68, however for digital output 2

High

77

Reserved

1

If neither of the digital inputs is programmed for left or right enable, then the actuation of a fixed frequency or jog frequency will

enable the frequency inverter. The rotation field direction depends on the sign of the setpoint.

2

Also effective for bus control (RS232, RS485, CANbus, CANopen, DeviceNet, Profibus, InterBus, AS-Interface)

3

Function cannot be selected via BUS IO In Bits

Parameter

{Factory setting}

Setting value / Description / Note

Device

Supervisor

Parameter
set

P426

Quick stop time

(Quick stop time)

S

P

0 ... 320.00 sec

{ 0.10 }

Setting of the stop time for the fast stop function which can be triggered either via a digital input,
the bus control, the keyboard or automatically in case of a fault.

Emergency stop time is the time for the linear frequency decrease from the set maximum
frequency (P105) to 0Hz. If an actual setpoint <100% is being used, the emergency stop time is
reduced correspondingly.

P427

Emerg. stop on error

(Emergency stop on fault)

S

0 ... 3

{ 0 }

Activation of automatic emergency stop following error

0 = Disabled: Automatic emergency stop following fault is deactivated

1 = Mains supply failure: Automatic emergency stop following mains supply failure

2 = In case of faults: Automatic emergency stop following error

3 = Fault or mains failure: Automatic emergency stop in case of fault or mains failure

P428

Automatic start

(Automatic start)

S

0 ... 1

{ 0 }

In the standard setting (P428 =0 Off) the inverter requires a flank to enable (signal change
from "low high") at the relevant digital input.

In the setting On 1 the FI reacts to a High level. This function is only possible if the FI is
controlled using the digital inputs. (see P509=0/1)

In certain cases, the FI must start up directly when the mains are switched on. For this P428 = 1
On can be set. If the enable signal is permanently switched on, or equipped with a cable
jumper, the FI starts up immediately.

NOTE:

(P428) not "ON" if (P506) = 6, Danger! (See note on (P506))

NOTE:

The "Automatic Start" function can only be used if a digital input of the frequency
inverter (DIN

1 … DIN 4) is parameterised to the function "Enable Right" or "Enable

Left" and this input is permanently set to "High". The digital inputs of the technology
units (e.g.:SK CU4 - IOE) do not support this "Automatic Start" function.

NOTE:

The "Automatic Start" function can only be activated if the frequency inverter has
been parameterised to local control ((P509) setting { 0 } or { 1} ).