beautypg.com

2 information (i/o - extension) – NORD Drivesystems BU0180 User Manual

Page 138

background image

SK 180E Manual for frequency inverters

138

Pre-series version

BU 0180 GB-0914

6.2.2

Information (I/O - extension)

Parameter

Setting value / Description / Note

Device

Supervisor

Parameter
set

P170

... [-01]

... [-02]

Present error

(Present error)

0 ... 9999

Actual error present. Further details in Section 7 "Operating status messages".

… [-01 ] = Current module error

… [-02 ] = Last module error

Possible displayed values:

1000 = EEPROM error

1030 = System bus OFF

2000 = DIP changed

2001 = DIP configuration error / not permissible

2010 = Analog output error

2020 = Inverter does not support SK xU4-IOE

(Error not associated with SK 1x0E possible)

P171

... [-01]

...

... [-03]

Software version

(Software version/ revision)

0.0 ... 9999.9

This parameter shows the software and revision numbers in the module. Array [-03] provides
information about any special versions of the hardware or software A zero stands for the
standard version.

… [-01] = Software Version 1, "Version number":

(e.g.: V1.0)

… [-02] = Software Version 2, "Version number":

(e.g.: R1)

… [-03] = Software Version 3, "Version number":

(e.g.: 0)

P172

Configuration level

(Configuration level)

0 ... 2

This parameter displays the functions or variants integrated into the module.

0 = Internal bus module (SK CU4-

…)

1 = External bus module (SK CU4-

…)

2 = BUS Technology Unit via SPI