beautypg.com

NORD Drivesystems BU0180 User Manual

Page 146

background image

SK 180E Manual for frequency inverters

146

Pre-series version

BU 0180 GB-0914

Display in the
SimpleBox

Fault

Text in the ParameterBox

Cause

Remedy

Group

Details in
P700[-01] /
P701

E015

15.0

Reserved

E016

16.0

Motor phase error

A motor phase is not connected.

Check P539

Check motor connection

16.1

Magn. current monitoring
"Magnetisation current
monitoring"

Required exciting current not achieved at
moment of switch-on.

Check P539

Check motor connection

E018

Reserved

E019

19.0

Parameter ident.
"Parameter identification"

Automatic identification of the connected motor was
unsuccessful

Check motor connection

Check preset motor data (P201 … P209)

19.1

Star delta incorr.
"Motor star/delta switching
incorrect"

E020

E021

20.0

Reserved

System error in program execution, triggered by EMC
interference.

Please comply with wiring guidelines in Section 2.5.

Use additional external mains filter. (Section 9.3 / 9.3.3 (EMC))

FI must be very well earthed.

20.1

Watchdog

20.2

Stack overflow

20.3

Stack underflow

20.4

Undefined opcode

20.5

Protected Instruct.
“Protected Instruction“

20.6

Illegal word access

20.7

Illegal Inst.

Access

“Illegal Instruction Access”

20.8

Prog.mem. error
"Program memory error"
(
EEPROM error)

20.9

Reserved

21.0

NMI error
(not used by hardware)

21.1

PLL error

21.2

ADU error

21.3

PMI error

21.4

Userstack Overflow