beautypg.com

3 setpoint converter, sk cu4-rel, Setpoint converter, sk cu4-rel – NORD Drivesystems BU0180 User Manual

Page 57

background image

3 Options

BU 0180 GB-0914

Pre-series version

57

3.3.3

Setpoint converter, SK CU4-REL

The analog inputs of SK 1x0 E series frequency inverters and the optional mains units SK xU4-24V can only
process unipolar setpoint values referenced to GND (0/2 … 10 V; 0/4 … 20 mA). If a bipolar setpoint
(10V … + 10 V) is available, this must be converted to a 0 … 10 V signal by means of an SK CU4-REL setpoint
converter.

Two coupling relays are integrated into the module. These are controlled via the digital outputs of the
frequency inverter and can be used as openers or closers according to their connection.

+24V control voltage

2x Analog inputs (-

10 … +10 V)

2x digital inputs

2x Analog outputs (0 … 10 V)  only for transfer to the
frequency inverter

2x Relay outputs (each configured as changeovers)

Max. permissible continuous relay current: 1000 mA (

≤30 V DC)

incl. cable set

The terminal bar of the customer unit SK CU4-REL-

… is divided into two potential levels (potential

separation max. 50 V DC). On delivery, these are connected together with a plug-in jumper.

The bipolar analog signals must be connected to input terminals 114 or 116. Via the analog outputs
(Terminal 117 or 118) the signals which are transformed to 0...10V can be accessed and transferred to the
frequency inverter for further processing. In order to ensure the function of the analog signal converter, the
10V DC reference voltage of the frequency inverter must be wired to the reference potential of the setpoint
source(s) of the SK CU4-REL

Up to 2 digital signals can be transferred to the coupling relays from the frequency inverter. Regardless of
the wiring, both relays each provide the possibility of accessing an opening (NC) or a closing (NO) signal.

The module must be supplied with 24V DC.

R21

R22

R24

R

11

R

12

R14

40

C2

C1

1

1

8

1

1

7

1

1

6

1

1

4

1

1

1

1

1

2

44

Relay 1

Connection of the 24V power
supply from the SK 1x0E

AOUT connection of the
SK CU4 to AIN of the SK 1x0E

24V

AGND / 0V

Connection to the terminal bar

of the SK CU4-REL-

10V REF.

DI1

AOUT1

R11 / R14 = NO

R11 / R12 = NC

SK CU4-

SK 1x0E-

Digital control in the SK CU4 via
DO from the SK 1x0E

AIN1

Connection for bipolar analog signals

Potential level:

Analog

Potential level:

Digital / Relay

11

12*

43

1

16

14

40

3

AIN2

AOUT2

DI2

Relay 2

R21 / R24 = NO

R21 / R22 = NC

* Terminal 12 or Terminal 40

GND / 0V

Potential level jumper connections :

Illustration: Potential levels with analog and digital
connection

Similar to illustration