NORD Drivesystems BU0180 User Manual
Page 109
6 Parameterisation
BU 0180 GB-0914
Pre-series version
109
Parameter
{Factory setting}
Setting value / Description / Note
Device
Supervisor
Parameter
set
P483
[-01]
...
...
[-10]
Hyst. BusIO Out Bits
(Hysteresis of bus I/O Out bits)
S
1 … 100 %
{ all 10 }
Difference between switch-on and switch-off point to prevent oscillation of the output signal.
[-01] = Bus / AS-i Dig Out1
(Bus IO Out Bit 0 + AS-i 1)
[-02] = Bus / AS-i Dig Out2
(Bus IO Out Bit 1 + AS-i 2)
[-03] = Bus / AS-i Dig Out3
(Bus IO Out Bit 2 + AS-i 3)
[-04] = Bus / AS-i Dig Out4
(Bus IO Out Bit 3 + AS-i 4)
[-05] = Bus / IOE Dig Out1
(Bus IO Out Bit 4 + DO 1 of the first SK xU4-IOE (DigOut 02))
[-06] = Bus / IOE Dig Out2
(Bus IO Out Bit 5 + DO 2 of the first SK xU4-IOE (DigOut 03))
[-07] = Bus / 2nd IOE Dig Out1
(Flag1 + DO 1 of the second SK xU4-IOE (DigOut 04))
[-08] = Bus / 2nd IOE Dig Out2
(Flag2 + DO 2 of the second SK xU4-IOE (DigOut 05))
[-09] = Bit 10 BUS status word
[-10] = Bit 13 BUS status word
NOTE:
Details for the use of the relevant bus systems can be found in the applicable supplementary
bus manual.