4 option slots in the device – NORD Drivesystems BU0180 User Manual
Page 22
SK 180E Manual for frequency inverters
22
Pre-series version
BU 0180 GB-0914
2.1.4
Option slots in the device
Size 1:
Size 2:
The above drawings indicates the different installation locations for optional modules. Option slot 1 is used
for the mounting of an internal customer interface (e.g. bus module). Option location 2 for installing an
internal brake resistor is only present in size 2. The brake resistor may only be installed at the factory
and must therefore be taken into account in the order. External bus modules, 24 V power supplies can
be implemented at option locations 3L or 3R. Option locations 4 and 5 are used for the installation of M12
sockets or plug connectors or for cable glands. Only one option per option location is possible.
Option
location
Position Meaning
Size
Sizes 1 - 2
Comments
1
Internal
Mounting location for customer units SK CU4-
…
2
Internal
Installation location for internal brake resistor
Only for size 2
3*
on side
Mounting location for
external technology units SK TU4-
…
Power plug connector (e.g. HARTING)
3 A/B*
on side
Cable gland
M25
Not available if loca-
tion 3 is occupied or
SK TU4-
… is fitted.
4 *,
5 *
on side
Cable gland
M16
Not available if
SK TU4-
… is fitted.
* R and L (right and left side)
– for motor installation: viewed from the fan wheel toward the motor shaft
3BR 3AR
3R
4R
5R
1
4L
5L
3AL
3BL
3L
1
3BR 3AR
3R
4R
5R
1
4L
5L
3AL
3BL
3L
1
2
2