5 extra functions – NORD Drivesystems BU0180 User Manual
Page 110
SK 180E Manual for frequency inverters
110
Pre-series version
BU 0180 GB-0914
6.1.5
Extra functions
Parameter
{Factory setting}
Setting value / Description / Note
Device
Supervisor
Parameter
set
P501
Inverter name
(Inverter name)
A…Z
(char)
{ 0 }
Free input of a designation (name) for the device (max. 20 characters). With this, the frequency
inverter can be uniquely identified for setting with NORD CON - software or within a network.
P502
[-01]
...
[-03]
Master function value
(Master function value)
S
P
0 ... 24
{ all 0 }
Selection of up to 3 master values of a Master for output to a bus system (see P503).
The assignment of these master values to the slave is carried out via (P546).
(for definition of frequencies see Section 9.10):
[-01] = Master value 1
[-02] = Master value 2
[-03] = Master value 3
Selection of possible setting values for master values:
0 = Off
1 = Actual frequency
2 = Actual speed
3 = Current
4 = Torque current
5 = Digital IO status
6 = ... 7 reserved
8 = Setpoint frequency
9 = Error number
10 = ... 11 reserved
12 = Bus IO Out Bits 0-7
13 = ... 16 reserved
17 = Value analog input 1 P400[-01])
18 = Value analog input 2 (P400[-02])
19 = Setpoint freq. master value,
"Setpoint frequency master value"
20 = Set freq. after ramp master value,
"Setpoint frequency from ramp master
value“
21 = Actual freq.wo. slip master
"Actual frequency without slip master
value"
22 = Speed encoder
23 = Actual frequency with slip
"Actual frequency with slip"
24 = Master value actual freq. with slip
“Master value, actual freq. with slip“
delete