NORD Drivesystems BU0180 User Manual
Page 155
8 Technical data
BU 0180 GB-0914
Pre-series version
155
Size 2
Device type:
SK 1x0E…
-750-323-B
-111-323-B
-151-323-B
Nominal motor power
(4-pole standard motor)
230 V
0.75 kW
1.1 kW
1.5 kW
240 V
1 hp
1½ hp
2 hp
In
p
u
t
Mains voltage
1~ /3~ 230 V
1/3 AC
3 AC
200 ... 240V,
10%, 47 ... 63 Hz
Typical input current
at 230V
1~ / 3~ rms
10.6 A / 7 A
14 A / 9.2 A
- / 11.2 A
1~ / 3~ FLA
10.6 A / 7 A
14 A / 9.2 A
- / 11.2 A
Rec. mains fuse
1 AC
slow-acting [A]
16 A
16 A
16 A
Permissible mains
fuses (UL)
RK5 or faster
fuses,
min 230 V
30 A / 10A
30 A
30 A
Bussmann
FRS-R-30
FRS-R-30
FRS-R-30
Circuit breaker*
min. 230 V
25 A / 10A
25 A
25 A
O
u
tp
u
t
Output voltage
3~ 230 V
3 AC 0 - Mains voltage
Nominal output
current at 230V
rms
4.0 A
5.5 A
7.0 A
Motor
Assembly**
3.9 A
5.4 A
6.9 A
Wall-mounted**
3.9 A
1~4.4 A / 3~5.4 A
6.9 A
Min. braking resistor
-
100
75
Recommended braking
resistor
Section 2.3
-
100
100
Motor mounting (ventilation with motor fan)
Max. continuous power / max. continuous current:
(for single phase operation, the deviating
value is shown in brackets)
S1-50°C
S1-40°C
0.75 kW / 4.0 A (3.4 A)
0.75 kW / 4.0 A
0.75 kW / 4.0 A
1.1 kW / 5.5 A
1.1 kW / 5.5 A
1.5 kW / 7.0 A
Max. permissible ambient temp. with nominal output current
S1
S3
70%ED 10min
S6
70%ED 10min (100% / 20%Mn)
1~ 40°C / 3~ 50°C
50°C
50°C
40°C
50°C
50°C
40°C
50°C
50°C
Wall mounting (unventilated)
Max. continuous power / max. continuous current:
(for single phase operation, the deviating
value is shown in brackets)
S1-50°C
S1-40°C
0.75 kW / 4.0 A (3.4 A)
0.75 kW / 4.0 A
0.75 kW / 4.0 A (3.6 A)
0.75 kW / 4.5 A (4.4 A)
1.1 kW / 5.5 A
1.5 kW / 6.5 A
Max. permissible ambient temp. with nominal output current
S1
S3
70%ED 10min
S6
70%ED 10min (100% / 20%Mn)
1~ 40°C / 3~ 45°C
50°C
50°C
1~ 30°C / 3~ 40°C
1~ 40°C / 3~ 50°C
1~ 40°C / 3~ 50°C
30°C
40°C
40°C
* Circuit Breaker (inverse time trip type) as per UL489
** FLA (S1-40 °C)